Nivotester FTR525
Hauser
29
Commissioning
Example:
018
1M
2 1 1 2
2
1
3
4
Max. detection range
Set detection range
Current measured value within the
set detection range
Current measured value at the
limit of the set detection range
Current measured value outside
of the set detection range
000
043
036
17 Manual adjustment lower limit (LL) level limit detection display with examples
1 Set detection range (= 0-100% of signal output)
2 Lower limit (adjustable using this function)
3 Percentage value for the lower limit relative to the maximum possible detection range
4 Current measured value
The microwave barrier is optimally adjusted to match the application when the lower
detection limit (function
2112
) corresponds to the minimum signal strength and the
upper detection limit (function
2113
) corresponds to the maximum signal strength.
Application-specific
detection range
18 Optimal adjustment
Procedure for optimal adjustment:
Manually adjust the lower limit to match the application-specific minimum measured
value.
Manually adjust the upper limit (function
2113
) to match the application-specific
maximum measured value.
The detection range can also be set to be lower or higher, for example if a turndown of the
signal output is desired.
8�4�1�3 Manual adjustment upper limit (UL) level limit detection
Application
2000
→
Sensor
2100
→
Limit detection
2110
→
Manual adjustment UL
2113
This function can be used to change the upper limit of the set detection range using
(for increasing the set detection range 0 to 100 %) or (for reducing the set detection
range 0 to 100 %). To assist with adjustment, the current measured value is shown
alongside the set detection range (see example function
2112
).