Proline Promag 51
Technical data
Hauser
83
10.1.6
Operating conditions: rated operating conditions
All specifications in accordance with MID, Annex I and Annex MI-001
Dimensions and flow range
Accuracy class
The following error limits apply
± 2 % (for flow rates: Q
2
Q < Q
4
)
± 5 % (for flow rates: Q
1
Q < Q
2
)
Medium temperature range
Cold water +0.1 to +30 °C
Limiting medium pressure
range (nominal pressure)
Promag W
• EN 1092-1 (DIN 2501)
– PN 6 (DN 350 to 800)
– PN 10 (DN 200 to 800)
– PN 16 (DN 65 to 800)
– PN 25 (DN 200 to 800)
– PN 40 (DN 25 to 150)
Promag P
• EN 1092-1 (DIN 2501)
– PN 10 (DN 200 to 600)
– PN 16 (DN 65 to 600)
– PN 25 (DN 200 to 600)
– PN 40 (DN 15 to 150)
Orientation
Any orientation (vertical, horizontal)
Restrictions and additional installation instructions
Mechanical ambient
conditions
Class: M2
Climatic ambient conditions
–40 to +55 °C (–40 to +131 °F); condensation possible
!
Note!
At ambient temperatures below –20 (–4 °F) the readability of the display may be impaired.
Sensor:
• Carbon steel flange material: –10 to +60 °C (+14 to +140 °F)
• Stainless steel flange material: –40 to +60 °C (–40 to +140 °F)
"
Caution!
The permitted temperature range for the liner may not be exceeded or undershot
(
"Medium temperature range").
Note the following points:
• Install the device at a shady location. Avoid direct sunlight, particularly in warm climatic regions.
• If both fluid and ambient temperatures are high, install the transmitter at a remote location from
the sensor.
Electromagnetic ambient
conditions
Class: E2