Operational safety
Note the following points:
• Measuring systems for use in hazardous environments are accompanied by separate
Ex documentation, which is an integral part of these Operating Instructions. Strict compliance
with the installation instructions and ratings as stated in this supplementary documentation is
mandatory. The symbol on the front of this documentation indicates the approval and the
inspection authority (e.g.
0
Europe,
2
USA,
1
Canada).
• The measuring device complies with the general safety requirements in accordance with
EN 61010-1, the EMC requirements of IEC/EN 61326, and NAMUR recommendation NE 21
and NE 43.
• Due to the performance rate in the electronic components, the maximum heating of the outer
housing surfaces is 10 K. When hot fluids are passed through the measuring tube, the surface
temperature of the housing increases. With regard to the sensor, in particular, you should expect
temperatures that can be close to the fluid temperature.
If the temperature of the fluid is high, ensure staff are protected against burns and scalds.
• The manufacturer reserves the right to modify technical data without prior notice. Your
Hauser distributor will supply you with current information and updates to these
Operating Instructions.
1.4
Return
• Do not return a measuring device if you are not absolutely certain that all traces of hazardous
substances have been removed, e.g. substances which have penetrated crevices or diffused
through plastic.
• Costs incurred for waste disposal and injury (burns, etc.) due to inadequate cleaning will be
charged to the owner-operator.
• Please note the measures on
1.5
Notes on safety conventions and icons
The devices are designed to meet state-of-the-art safety requirements, have been tested, and left the
factory in a condition in which they are safe to operate. The devices comply with the applicable
standards and regulations in accordance with EN 61010-1 "Safety requirements for electrical
equipment for measurement, control and laboratory use".
The devices can, however, be a source of danger if used incorrectly or for other than the designated
use. Consequently, always pay particular attention to the safety instructions indicated in these
Operating Instructions by the following icons:
#
Warning!
"Warning" indicates an action or procedure which, if not performed correctly, can result in injury
or a safety hazard. Comply strictly with the instructions and proceed with care.
"
Caution!
"Caution" indicates an action or procedure which, if not performed correctly, can result in incorrect
operation or destruction of the device. Comply strictly with the instructions.
!
Note!
"Note" indicates an action or procedure which, if not performed correctly, can have an indirect
effect on operation or trigger an unexpected response on the part of the device.