![Enclustra ME-XU1-15EG-1E-D12E-G1 User Manual Download Page 62](http://html1.mh-extra.com/html/enclustra/me-xu1-15eg-1e-d12e-g1/me-xu1-15eg-1e-d12e-g1_user-manual_2405971062.webp)
5.2
Recommended Operating Conditions
Table 50 indicates the recommended operating conditions for XU1 SoC module. The values given
are for reference only; for details please refer to the Zynq Ult MPSoC, DC and AC Switching Char-
acteristics Datasheet [21].
Symbol
Description
Rating
Unit
VCC_MOD
Supply voltage relative to GND
4.75 to 15.75
V
VCC_BAT
Supply voltage for MPSoC battery-backed RAM and battery-
backed RTC
2.7 to 3.6
V
VCC_IO_[x]
Output drivers supply voltage relative to GND
Refer to
V
VCC_CFG_[x]
Section 2.9.5
V_IO
I/O input voltage relative to GND
-0.2 to V
CCO
+0.2
V
Temperature
Temperature range for extended temperature modules (E)
0 to +85
◦
C
Temperature range for industrial modules (I)
-40 to +85
◦
C
Table 50: Recommended Operating Conditions
Warning!
*
The components used on the hardware are specified for the relevant temperature range. The user
must provide adequate cooling in order to keep the temperature of the components within the specified
range.
D-0000-428-001
62 / 66
Version 13, 15.08.2019