![Enclustra ME-XU1-15EG-1E-D12E-G1 User Manual Download Page 61](http://html1.mh-extra.com/html/enclustra/me-xu1-15eg-1e-d12e-g1/me-xu1-15eg-1e-d12e-g1_user-manual_2405971061.webp)
5
Operating Conditions
5.1
Absolute Maximum Ratings
Table 49 indicates the absolute maximum ratings for XU1 SoC module. The values given are for
reference only; for details please refer to the Zynq Ult MPSoC, DC and AC Switching Characteristics
Datasheet [21].
Symbol
Description
Rating
Unit
VCC_MOD
Supply voltage relative to GND
-0.5 to 16
V
VCC_BAT
Supply voltage for MPSoC battery-backed RAM and
battery-backed RTC
0 to 3.6
V
VCC_IO_B47
Output drivers supply voltage relative to GND
-0.5 to 3.4
V
VCC_IO_B48
VCC_CFG_MIO
Output drivers supply voltage relative to GND
-0.5 to 3.63
V
VCC_IO_B64
Output drivers supply voltage relative to GND
-0.5 to 2.0
V
VCC_IO_B65
VCC_IO_B66
V_IO
I/O input voltage relative to GND
-0.5 to V
CCO
+0.5
V
Temperature
Temperature range for extended temperature modules (E)
0 to +85
◦
C
Temperature range for industrial modules (I)
-40 to +85
◦
C
Table 49: Absolute Maximum Ratings
D-0000-428-001
61 / 66
Version 13, 15.08.2019