background image

12434-7-0706

Page 9

On solid wall, when using wall studs for attachment of wall mounting 

bracket, fasten wall mounting bracket to wall studs with (2) #10 x 

1 1/2" (38mm) screws provided and fasten  (2) additional #10 x 1 

1/2" (38mm) screws provided through the wall mounting bracket 

and into the solid wall. 
On sheet rock, when using wall studs for attachment of wall mounting 

bracket, fasten wall mounting bracket to wall studs with (2) #10 

x 1 1/2" (38mm) screws provided and by using wall opening for 

access, fasten 2 additional #10 x 1 1/2" (38mm) screws and (2) 

Tinnerman nuts provided through the wall mounting bracket and 

into the sheet rock.

Attaching Furnace To Wall Mounting Bracket  

Hang furnace on wall mounting bracket by aligning (2) tabs on wall 

mounting bracket with (2) slots located on inner casing top.
The inner casing bottom is to be fastened to the wall.  On solid wall, 

fasten inner casing bottom with (2) #10 x 1 1/2" (38mm) screws 

provided.  On sheet rock wall, fasten inner casing bottom with (2) 

toggle bolts provided.

Cutting Vent Tubes

This is the most important part of the installation.  With the furnace 

installed on wall the 6" (152mm) diameter air inlet tube and the 4" 

(102mm) diameter flue outlet tube are to be marked and cut using 

the following procedure.

1.  Attach 6" (152mm) diameter air inlet tube onto the collar of air 

drop assembly.  Be sure 6" (152mm) diameter air inlet tube is 

placed as far as possible onto the collar of the air  drop assembly.  

Mark the 6" (152mm) diameter air inlet tube 1/2" (13mm) beyond 

the outside wall.  Remove 6" (152mm) diameter air inlet tube 

from collar of air drop assembly.

2.  Attach 4" (102mm) diameter flue outlet tube onto flue outlet 

collar on combustion chamber.  Be sure 4" (102mm) diameter 

flue outlet tube is placed as far as possible onto the collar of 

flue outlet.  Mark the 4" (102mm) diameter flue outlet tube 2 

1/2" (64mm) beyond the outside wall.  Remove 4" (102mm) 

diameter flue outlet tube from collar of flue outlet on combustion 

chamber.

3.  Mark or wrap tape completely around the tubes at the marked 

points to help in making a true cut.  Do not crimp or enlarge 

tubes.

Installing Vent Assembly

1.  Place provided caulking beneath the edge of the outside mounting 

plate.  Use additional caulking to correct uneven wall surface, 

such as clapboard.

2.  Attach 6" (152mm) diameter air inlet tube onto the collar of 

air drop assembly.  Attach caulked, outside mounting plate into 

the 6" (152mm) diameter air inlet tube.  Position the outside 

mounting  plate  so  that  6"  (152mm)  diameter  air  inlet  tube 

has a slight downward slope to the outside.  The downward 

slope is necessary to prevent the entry of rainwater.  Attach 

outside mounting plate to exterior wall with (4) #10 x 1 1/2" 

(38mm)screws provided.

3.  Apply furnace cement to 4" (102mm) diameter flue outlet collar 

on combustion chamber and to 4" (102mm) diameter  collar on 

vent cap.  Attach 4" (102mm) diameter flue outlet tube onto flue 

outlet collar on combustion chamber.  Attach vent cap into the 

4"(102mm) diameter flue outlet tube.  Attach vent cap to outside 

mounting plate with (3) #10 x 1/2" (13mm) screws provided.

4.  Installation is completed.

Reassembly And Resealing Vent-Air Intake System

When vent-air intake system is removed for servicing the furnace, 

the following steps will assure proper reassembly and resealing of 

the vent-air intake assembly.

1.  Remove old furnace cement from flue outlet collar on combustion 

chamber and collar of vent cap.  Remove old furnace cement 

from both ends of 4" (102mm) diameter flue outlet tube.

2.  Remove old caulking beneath the edge of the outside mounting 

plate.   Apply  new  caulking  beneath  the  edge  of  the  outside 

mounting plate.  Use additional caulking to correct uneven wall 

surface, such as clapboard.

3.  Attach  6" (152mm) diameter air inlet tube onto the collar of 

air drop assembly.  Attach caulked, outside mounting plate into 

the 6" (152mm) diameter air inlet tube.  Position the outside 

mounting plate so that 6" (152mm) diameter air inlet tube has 

a slight downward slope to the outside.  The downward slope 

is necessary to prevent the entry of rainwater.  Attach outside 

mounting plate to exterior wall with (4) #10 x 1 1/2" (38mm) 

screws provided.

4.  Apply furnace cement to 4" (102mm) diameter flue outlet collar 

on combustion chamber and to 4" (102mm) diameter  collar on 

vent cap.  Attach 4" (102mm) diameter flue outlet tube onto flue 

outlet collar on combustion chamber.  Attach vent cap into the 4" 

(102mm) diameter flue outlet tube.  Attach vent cap to outside 

mounting plate with (3) #10 x 1/2" (13mm) screws provided.

5.  Reassembly  and  resealing  vent-air  intake  system  is 

completed.

Installing a Vent Near a Window Ledge, Other Type of Projection 

or on Vinyl Siding

Direct  vent  furnaces  are  designed  to  be  installed  on  a  uniform 

outside wall.  When the wind comes from any angle (up, down  or 

from either side), it must hit the vent cap equally over both the air 

inlet and the flue outlet portions of the vent.  Any wall projection, 

such as a door or window casing, which disturbs the wind on one 

side of the air inlet section will result in back pressure on the flue 

section smothering the flame and eventual pilot outage.
When the vent cap is to be installed on vinyl siding or it appears that 

a projection within 6" (152mm) of any side of the air inlet section 

could shield the air inlet section, the entire vent should be supported 

away from the wall at least the distance of the projection. 2" x 4" 

(51mm x 102mm) framing whose outside dimensions match the 

overall dimensions of the mounting plate is recommended.  The 2" 

x 4" (51mm x 102mm) framing protects vinyl siding from possible 

warpage or discoloration.  All joints can then be sealed and painted. 

The wall depth plus the additional depth of the 2" x 4" (51mm x 

102mm) framing should not exceed a total depth of 13" (330mm) 

for DV-25 and DV-35.  (See Figure 5)
Vinyl siding vent kit, DV-822,  is available from Empire Comfort 

Systems, Inc.  The depth is 3" (76mm), which enables the vent cap 

to be extended away from vinyl siding or projections.  The wall 

depth plus the additional 3" (76mm) depth of the vinyl siding vent 

INSTALLATION INSTRUTIONS (continued)

Summary of Contents for DV-25-2SG

Page 1: ...onvertible for use with other gases unless a certi ed kit is used Installer Leave these instructions with the consumer Consumer Retain these instructions for future use Donotstoreorusegasolineorother...

Page 2: ...ations 6 Gas Supply 7 Clearances 8 Installation Instructions 8 10 Thermostat Location 10 Lighting Instructions 11 Pilot Flame Characteristics 12 Main Burner Flame Characteristics 12 Maintenance 13 Tro...

Page 3: ...n More frequent cleaning may be required due to excessive lint from carpeting bedding materials etc It is imperative that control compartments burners and circulating air passageways of the appliance...

Page 4: ...s perform service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP Gas Odor fade due to oxidation by rust or adsorption on w...

Page 5: ...iredinaccordance with the above provisions shall comply with NFPA 720 and be ANSI UL 2034 listed and IAS certi ed 3 SIGNAGE Ametalorplasticidenti cationplateshallbe permanently mounted to the exterior...

Page 6: ...ed so it is not subject to physical damage by a moving vehicle Quali ed Installing Agency Installationandreplacementofgaspiping gasutilizationequipment or accessories and repair and servicing of equip...

Page 7: ...o aid in servicing It is required by the National Fuel Gas Code that a drip line be installed near the gas inlet This should consist of a vertical length of pipe tee connected into the gas line that i...

Page 8: ...gulator malfunction the six 6 1 83m feet distance will reduce the chance of gas entering the vent cap Location of Furnace Pickalocationonanoutsidewallwithaclearspaceof28 711mm high by 49 124cm wide in...

Page 9: ...cap into the 4 102mm diameter ueoutlettube Attachventcaptooutside mounting plate with 3 10 x 1 2 13mm screws provided 4 Installation is completed Reassembly And Resealing Vent Air Intake System When...

Page 10: ...due to spiders System Check Figure 6 Amillivoltmeterisrequiredtocheckthesystem Millivoltreadings should be Across the thermopile terminals 400 450 millivolts with thermostat OFF Across the thermopile...

Page 11: ...clockwise to OFF Do not force 5 Replace casing front assembly 1 STOP Read the safety information above 2 Set the thermostat to lowest setting 3 Turn off all electric power to the appliance if appli ca...

Page 12: ...ng on the inner casing bottom On Propane gas if a whistling noise resonation occurs screw air adjustment bolt into the chamber support in order to reduce the amount of primary air If the whistling noi...

Page 13: ...s a See Page 12 Primary Air Adjustment b Reduce manifold pressure c Size main burner ori ce with a drill bit For DV 25 use 54 drill bit For DV 35 use 50 drill bit Removing Main Burner 1 Disconnect the...

Page 14: ...ifold 30 R 191 Manifold Union Assembly 31 R 5600 Gas Valve Nat 7000 MVRLC 31 R 5601 Gas Valve LP 7000 MVRLC 32 DV 1003 Valve Bracket 33 DV 764 Gasket Chamber Support DV 765 2 Each Required 34 DV 908 V...

Page 15: ...12434 7 0706 Page 15 PARTS VIEW...

Page 16: ...l from black hot wire on motor 4 Attach green ground wire beneath one of the 10 x 1 2 13mm screws on the blower housing Fan Control The automatic fan control is located in the switch box The switch bo...

Page 17: ...ng 2 or 3 drops each time If the motor fails to start and hums it could be a tight bearing due to lack of oil This may be corrected by pouring kerosene in the oil holes allowing to stand for a few hou...

Page 18: ...12434 7 0706 Page 18 SERVICE NOTES...

Page 19: ...12434 7 0706 Page 19 SERVICE NOTES...

Page 20: ...12434 7 0706 Page 20 Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 PH 618 233 7420 or 800 851 3153 FAX 618 233 7097 or 800 443 8648 info empirecomfort com www empirecomfort com...