30411-17-0120
Page 6
CLEARANCES
COMBUSTIBLE MATERIAL
Do not attach combustible material to the mantel of your fireplace.
This is a fire hazard.
Figure 6
No greeting cards, stockings or ornamentation of any type should be
placed on or attached to the fireplace. This is a heating appliance.
The flow of heat can ignite combustibles.
Minimum Wall and Ceiling Clearances
34 3/16”
(843mm)
4
(101mm)
”
Top of
Opening
Figure 4
This fireplace can be installed with zero clearance to
combustible material.
When facing the front of the appliance the minimum clearances to
combustible construction (material) are the following:
1. Clearances from the right side or left side of the fireplace opening
to any combustible wall or material should not be less than 4
inches.
2. Clearances from the top of the fireplace opening to the ceiling
should not be less than 34-3/16 inches.
Mantel Clearances for Built-in Installation
15 3/16”
(386mm)
Top of Opening
Mantel
14 7/16”
(367mm)
13 11/16”
(348mm)
12 15/16”
(329mm)
9 11/16”
(246mm)
8 15/16”
(227mm)
12”
(305mm)
10”
(254mm)
8”
(203mm)
6”
(152mm)
2 1/2”
(63mm)
4”
(102mm)
Figure 5