CAUTION: ALL WIRING SHOULD BE DONE BY A QUALIFIED ELECTRICIAN AND SHALL BE IN COMPLIANCE WITH ALL LOCAL, 

CITY AND STATE BUILDING CODES. BEFORE MAKING THE ELECTRICAL CONNECTION, MAKE SURE THAT MAIN POWER SUPPLY 

IS DISCONNECTED. THE APPLIANCE, WHEN INSTALLED, MUST BE ELECTRICALLY GROUNDED IN ACCORDANCE WITH LOCAL 

CODES OR, IN THE ABSENCE OF LOCAL CODES, WITH THE NATIONAL ELECTRICAL CODE ANSI/NFPA 70 (LATEST EDITION)

A factory installed junction box is located on the lower right 

hand side of the firebox. Wiring must be fed to the junction box 

and attached to the receptacle that is provided. Remove the 

knockout in the installed junction box to accept wiring into the 

junction box. Install a UL listed cable clamp (not supplied) in the 

knockout hole. Leave approximately 6" of wire in the junction box 

for connection.
Attach black wire to one side of the receptacle and white wire to 

opposite side of receptacle. The ground wire should be attached 

to the green (neutral) screw.
Install the receptacle into the junction box. Attach cover plate.

Keep the control compartment, logs and burner area surrounding the 

logs clean by vacuuming or brushing area at least twice a year.
THE LOGS CAN GET VERY HOT – HANDLE ONLY WHEN 

COOL.
Always turn off gas to the pilot before cleaning. For relighting, refer 

to lighting instructions located on the log set.

Never obstruct the flow of the combustion and ventilation air. Keep 

the front of the firebox clear of all obstacles and materials.

Screens must be closed during operation.

Figure 20

JUNCTION BOX WIRING INSTALLATION INSTRUCTIONS

MAINTENANCE

PARTS LIST

INDEX NO.

PART NUMBER

DESCRIPTION

VFS32FB0F

VFS36FB0F

VFS42FB0F

1

17247

17247

17247

TOP STANDOFF

2

10554

10554

10554

FRAMING BRACKET

3

17162

17162

17162

JUNCTION BOX ASSEMBLY

4

R3492

R3492

R3492

RECEPTACLE

5

R3491

R3491

R3491

COVER, JUNCTION BOX

6

25101

25101

25101

BLOWER COVER

7

R8213

R8202

R8202

SCREEN CURTAIN

8

20020

20145

19984

HOOD

9

R7051

R7052

R7053

ROD, SCREEN

10

R9292

R9292

R9292

HEARTH LEDGE, RIGHT

11

R9293

R9293

R9293

HEARTH LEDGE, LEFT

12

R9294

R9295

R9296

HEARTH LEDGE, CENTER

13

23004

23004

23004

HEARTH RETAINER

Summary of Contents for VFS32FB0F-4

Page 1: ...neigh bor s phone Follow the gas supplier s instruc tions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a quali fied installer service a...

Page 2: ...ion Instructions 5 7 Installing Hood 7 8 Gas Line Connection 8 Optional Single Speed Blower Installation Instructions 9 11 Junction Box Wiring Installation Instructions 12 Maintenance 12 Parts List 12...

Page 3: ...oval of such component part or accessory Any such action may create a possible fire hazard Consult your local building codes Firebox Screen The firebox screen must be in place when the firebox is oper...

Page 4: ...Grate Clearance The minimum clearance between the front legs of the grate and front edge of the firebox is 2 Leave at least 36 clearance from the front of the firebox CLEARANCES 45 6 3 MAX PERPENDICU...

Page 5: ...e on all four perimeter edges on the bottom of the unit Example Four 4 concrete masonry blocks If the firebox is installed directly on carpeting tile or other combustible material other than wood floo...

Page 6: ...SELECT REFERENCE LETTER FLUSH VFS32 VFS36 VFS42 A 41 1 8 41 1 8 41 1 8 B 34 1 2 39 1 2 43 1 2 C 23 7 16 23 7 16 23 7 16 D 26 3 8 31 3 8 35 3 8 E 38 1 2 38 1 2 38 1 2 F 31 36 40 G 31 3 4 31 3 4 31 3 4...

Page 7: ...ed with each firebox or optional hood MUST be installed before the firebox is used Failure to do so may create a possible fire hazard The hood is located inside the firebox on flush face units If bras...

Page 8: ...uce the supply tank pressure to a maximum of 14 w c This is in addition to the regulator fitted to the log set WARNING CONNECTION DIRECTLY TOAN UNREGULATED L P TANK CAN CAUSE EXPLOSION Install only a...

Page 9: ...for use with blower assembly A standard wall ON OFF wall switch or optional SCV1 Vari able Speed Control Kit should be installed to activate power to the Firebox and control the operation of the FBB5...

Page 10: ...inal Attach this terminal to the open terminal on the blower power cord See Figure 19 Connection B 10 Route the wires away from moving parts of the blower assem bly and retain wires together near the...

Page 11: ...a dirty blower wheel Remove fan and clean blower wheels Warning Unplugging of blower accessory will not stop the heater from cycling To turn off gas to the heater millivolt model push in gas control...

Page 12: ...he green neutral screw Install the receptacle into the junction box Attach cover plate Keep the control compartment logs and burner area surrounding the logs clean by vacuuming or brushing area at lea...

Page 13: ...28188 2 0114 Page 13 PARTS VIEW 1 2 8 9 7 3 4 5 6 13 11 12 10...

Page 14: ...xtended hoods that extend out 2 farther than the standard hoods to accommodate thicker surround materials Available as optional kits in Black Brass Ham mered Pewter and Stainless Steel finishes Contac...

Page 15: ...reet Hartford CT 06114 Phone 860 722 2433 Toll Free 800 243 9360 Fax 860 293 0479 Toll Free Fax 800 274 2004 Websites www fwwebb com www victormfg com Parts Heater Hearth and Grills MASTER PARTS DISTR...

Page 16: ...s Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question...

Reviews: