background image

28188-2-0114

Page 10

4.  Insert blower assembly into interior, bottom of firebox. Posi

-

tion blower assembly so that you align the notch on back of 

blower assembly with the center screw on firebox back, then 

push the blower assembly against firebox back. The blower 

wheel must be centered with the back wall of the firebox. The 

magnets on the back and bottom of blower assembly will suf-

ficiently hold blower assembly in place.

Note: 

For field installation of blower assembly, it may be easier to 

remove rear cover panel to install blower. This eliminates 

the need to remove brick liner panels, but the blower would 

have to be installed prior to installing the firebox into a wall 

or chase. 

See Figure 15.

5.  Once the blower assembly is in position, locate the plug but-

ton in the top right rear corner of the firebox. Remove the plug 

with a standard screwdriver and discard plug.

6.  Next, find the fan control switch and wire assembly. Feed the 

wires through the hole at the top of the firebox, and secure 

the fan control switch with (2) #6 screws provided. 

See Figure 

16.

7.  The fan control wires will slide down between the firebox and 

outer wrap near the blower assembly. 

See Figure 16

.

8.  One fan control wire will have a 1/4” female terminal that must 

be attached to the open terminal on the blower motor. 

See 

Figure 19, Connection A.

9.  The other fan control wire has a 1/4” male terminal. Attach this 

terminal to the open terminal on the blower power cord. 

See 

Figure 19, Connection B

10.  Route the wires away from moving parts of the blower assem-

bly and retain wires together near the blower motor using the 

plastic purse clip provided.

11.  To complete the installation, plug the power cord into the junc-

tion box receptacle at the right rear corner of the firebox outer 

wrap. 

See Figure 17.

12.  If room permits, the power cord can be located from the out-

side of the unit looking through the junction box access hole 

(with the junction box removed), then plug up the power cord 

before reinstalling the pre-wired junction box.

13.  Once all connections are made electrically, it is recommended 

that you test the blower fan control operation by turning on 

power to the blower (Caution: 110 Volt). Then apply heat to 

the fan control switch inside the firebox with a lighter or match 

until blower is activated. Once blower is activated, check for 

proper operation. Do not place hands near blower assembly 

or other wiring while power is on.

14.  Replace blower access plate and/or reinstall the brick liner 

panels if provided.

15.  This completes the installation of the optional FBB5 Blower kit 

accessory.

Note: 

This blower is equipped with a heat activated fan control 

switch. Blower will operate when the firebox warms up, and 

will turn off automatically when the firebox cools down.

REAR COVER PANEL MAY BE
REMOVED TO INSTALL BLOWER

REINSTALL COVER AFTER
BLOWER IS INSTALLED

Figure 15

NOTE: HOOD AND BRICK PANELS REMOVED FOR CLARITY

Figure 16

Figure 17

BLOWER POWER CORD

Summary of Contents for VFS32FB0F-4

Page 1: ...neigh bor s phone Follow the gas supplier s instruc tions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a quali fied installer service a...

Page 2: ...ion Instructions 5 7 Installing Hood 7 8 Gas Line Connection 8 Optional Single Speed Blower Installation Instructions 9 11 Junction Box Wiring Installation Instructions 12 Maintenance 12 Parts List 12...

Page 3: ...oval of such component part or accessory Any such action may create a possible fire hazard Consult your local building codes Firebox Screen The firebox screen must be in place when the firebox is oper...

Page 4: ...Grate Clearance The minimum clearance between the front legs of the grate and front edge of the firebox is 2 Leave at least 36 clearance from the front of the firebox CLEARANCES 45 6 3 MAX PERPENDICU...

Page 5: ...e on all four perimeter edges on the bottom of the unit Example Four 4 concrete masonry blocks If the firebox is installed directly on carpeting tile or other combustible material other than wood floo...

Page 6: ...SELECT REFERENCE LETTER FLUSH VFS32 VFS36 VFS42 A 41 1 8 41 1 8 41 1 8 B 34 1 2 39 1 2 43 1 2 C 23 7 16 23 7 16 23 7 16 D 26 3 8 31 3 8 35 3 8 E 38 1 2 38 1 2 38 1 2 F 31 36 40 G 31 3 4 31 3 4 31 3 4...

Page 7: ...ed with each firebox or optional hood MUST be installed before the firebox is used Failure to do so may create a possible fire hazard The hood is located inside the firebox on flush face units If bras...

Page 8: ...uce the supply tank pressure to a maximum of 14 w c This is in addition to the regulator fitted to the log set WARNING CONNECTION DIRECTLY TOAN UNREGULATED L P TANK CAN CAUSE EXPLOSION Install only a...

Page 9: ...for use with blower assembly A standard wall ON OFF wall switch or optional SCV1 Vari able Speed Control Kit should be installed to activate power to the Firebox and control the operation of the FBB5...

Page 10: ...inal Attach this terminal to the open terminal on the blower power cord See Figure 19 Connection B 10 Route the wires away from moving parts of the blower assem bly and retain wires together near the...

Page 11: ...a dirty blower wheel Remove fan and clean blower wheels Warning Unplugging of blower accessory will not stop the heater from cycling To turn off gas to the heater millivolt model push in gas control...

Page 12: ...he green neutral screw Install the receptacle into the junction box Attach cover plate Keep the control compartment logs and burner area surrounding the logs clean by vacuuming or brushing area at lea...

Page 13: ...28188 2 0114 Page 13 PARTS VIEW 1 2 8 9 7 3 4 5 6 13 11 12 10...

Page 14: ...xtended hoods that extend out 2 farther than the standard hoods to accommodate thicker surround materials Available as optional kits in Black Brass Ham mered Pewter and Stainless Steel finishes Contac...

Page 15: ...reet Hartford CT 06114 Phone 860 722 2433 Toll Free 800 243 9360 Fax 860 293 0479 Toll Free Fax 800 274 2004 Websites www fwwebb com www victormfg com Parts Heater Hearth and Grills MASTER PARTS DISTR...

Page 16: ...s Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question...