background image

28188-2-0114

Page 3

The installation must conform with local codes or, in 

the absence of local codes, with the National Fuel Gas 

Code, ANSI Z223.1 (latest edition) and to the National 

electrical Code, ANSI/NFPA70 (latest edition).
NOTE: Installation and repair should be done by a quali-

fied service person. The appliance should be inspected 

before use and at least annually by a qualified service 

person. More frequent cleaning may be required due 

to excessive lint from carpeting, bedding material, etc. 

It is imperative that control compartment, burners and 

circulating air passageways of the appliance be kept 

clean.

Any safety screen or guard removed for servicing an 

appliance must be replaced prior to operating the ap-

pliance. Provide adequate combustion and ventilation 

air.
The flow of combustion and ventilation air MUST NOT 

be obstructed.
Provide adequate clearance around air openings into 

the  combustion  chamber  and  adequate  accessibility 

clearance for servicing and proper operation. NEVER 

obstruct the front opening of the appliance.

This  Empire  Comfort  Systems,  Inc.  firebox  and  its 

components have been tested and will operate safely 

when installed in accordance with this installation 

manual.  Read  all  instructions  before  starting 

installation, then follow these instructions carefully 

during  installation  to  maximize  firebox  benefit  and 

safety. Report to your dealer any parts damaged in 

shipment.
The  Empire  Comfort  Systems,  Inc.  warranty  will  be 

voided by, and Empire Comfort Systems, Inc. disclaims 

any responsibility for the following actions:

-  Installation of any damaged firebox.

-  Modification of the firebox or any of the components 

parts thereof.

-  Installation  other  than  as  instructed  by  Empire 

Comfort Systems, Inc.

-  Installation and/or use of any component part 

or  accessory  not  approved  by  Empire  Comfort 

Systems,  Inc.  in  combination  or  assembly  with 

a  Empire  Comfort  Systems,  Inc.  firebox,  not 

withstanding any independent testing laboratory or 

other third party approval of such component part 

or accessory.

Any such action may create a possible fire hazard.

Consult your local building codes.
Firebox Screen.

The firebox screen must be in place when the firebox 

is operating.

Instructions to Installer

1.  Installer must leave instruction manual with owner after 

installation.

2.  Installer  must  have  owner  fill  out  and  mail  warranty  card 

supplied with firebox.

3.  Installer should show owner how to start and operate log set 

that is installed into firebox.

Important

All correspondence should refer to complete Model Number, 

Serial Number.
Notice:

 During initial firing of this firebox with a log set installed, its 

paint will bake out, and smoke will occur. To prevent triggering of 

smoke alarms, ventilate the room in which the unit is installed.

Qualified Installing Agency

Installation and replacement of gas piping, gas utilization equipment 

or accessories and repair and servicing of equipment shall be 

performed only by a qualified agency. The term "qualified agency" 

means any individual, firm, corporation or company which either in 

person or through a representative is engaged in and is responsible 

for (a) the installation or replacement of gas piping or (b) the 

connection, installation, repair or servicing of equipment, who is 

experienced in such work, familiar with all precautions required 

and has complied with all the requirements of the authority having 

jurisdiction.

State of Massachusetts: The installation must be made by 

a  licensed  plumber  or  gas  fitter  in  the  Commonwealth  of 

Massachusetts. The state of Massachusetts requires that 

a  flexible  appliance  connector  cannot  exceed  three  feet  in 

length.

Sellers of unvented propane or natural gas-fired supplemental 

room heaters shall provide to each purchaser a copy of 527 

CMR 30 upon sale of the unit.
In the State of Massachusetts, unvented propane and natural 

gas-fired space heaters shall be prohibited in bedrooms and 

bathrooms.

The installation must conform with local codes or, in the absence 

of local codes, with the National Fuel Gas Code, ANSI Z223.1/

NFPA 54.*

*Available from the American National Standards Institute, Inc., 

11 West 42nd St., New York, N.Y. 10036.

IMPORTANT SAFETY INFORMATION

INTRODUCTION

Summary of Contents for VFS32FB0F-4

Page 1: ...neigh bor s phone Follow the gas supplier s instruc tions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a quali fied installer service a...

Page 2: ...ion Instructions 5 7 Installing Hood 7 8 Gas Line Connection 8 Optional Single Speed Blower Installation Instructions 9 11 Junction Box Wiring Installation Instructions 12 Maintenance 12 Parts List 12...

Page 3: ...oval of such component part or accessory Any such action may create a possible fire hazard Consult your local building codes Firebox Screen The firebox screen must be in place when the firebox is oper...

Page 4: ...Grate Clearance The minimum clearance between the front legs of the grate and front edge of the firebox is 2 Leave at least 36 clearance from the front of the firebox CLEARANCES 45 6 3 MAX PERPENDICU...

Page 5: ...e on all four perimeter edges on the bottom of the unit Example Four 4 concrete masonry blocks If the firebox is installed directly on carpeting tile or other combustible material other than wood floo...

Page 6: ...SELECT REFERENCE LETTER FLUSH VFS32 VFS36 VFS42 A 41 1 8 41 1 8 41 1 8 B 34 1 2 39 1 2 43 1 2 C 23 7 16 23 7 16 23 7 16 D 26 3 8 31 3 8 35 3 8 E 38 1 2 38 1 2 38 1 2 F 31 36 40 G 31 3 4 31 3 4 31 3 4...

Page 7: ...ed with each firebox or optional hood MUST be installed before the firebox is used Failure to do so may create a possible fire hazard The hood is located inside the firebox on flush face units If bras...

Page 8: ...uce the supply tank pressure to a maximum of 14 w c This is in addition to the regulator fitted to the log set WARNING CONNECTION DIRECTLY TOAN UNREGULATED L P TANK CAN CAUSE EXPLOSION Install only a...

Page 9: ...for use with blower assembly A standard wall ON OFF wall switch or optional SCV1 Vari able Speed Control Kit should be installed to activate power to the Firebox and control the operation of the FBB5...

Page 10: ...inal Attach this terminal to the open terminal on the blower power cord See Figure 19 Connection B 10 Route the wires away from moving parts of the blower assem bly and retain wires together near the...

Page 11: ...a dirty blower wheel Remove fan and clean blower wheels Warning Unplugging of blower accessory will not stop the heater from cycling To turn off gas to the heater millivolt model push in gas control...

Page 12: ...he green neutral screw Install the receptacle into the junction box Attach cover plate Keep the control compartment logs and burner area surrounding the logs clean by vacuuming or brushing area at lea...

Page 13: ...28188 2 0114 Page 13 PARTS VIEW 1 2 8 9 7 3 4 5 6 13 11 12 10...

Page 14: ...xtended hoods that extend out 2 farther than the standard hoods to accommodate thicker surround materials Available as optional kits in Black Brass Ham mered Pewter and Stainless Steel finishes Contac...

Page 15: ...reet Hartford CT 06114 Phone 860 722 2433 Toll Free 800 243 9360 Fax 860 293 0479 Toll Free Fax 800 274 2004 Websites www fwwebb com www victormfg com Parts Heater Hearth and Grills MASTER PARTS DISTR...

Page 16: ...s Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question...

Reviews: