background image

33858-1-0615

Page 21

Two-function wireless remote control system for On/Off-Hi/

Lo operation of the AF-4000 gas control valve

FCC REQUIREMENTS

NOTICE: The manufacturer is not responsible for any radio 

or TV interference caused by unauthorized modifications to 

this equipment. Such modifications could void the user’s 

authority to operate the equipment.

INTRODUCTION

This remote control system was developed to provide a safe, 

reliable, and user-friendly remote control system for use with 

the AF-4000 gas control valve used with some gas heating 

appliances. The system operates on radio frequencies (RF) 

within a 20-foot range using non-directional signals. The system 

operates on one of 255 factory-programmed security codes; the 

remote receiver must learn the transmitter code prior to initial 

use.

TRANSMITTER

This remote control Transmitter allows the user to turn the 

fireplace on and off, and adjust the flame height.

The transmitter operates with a 12V battery (included). 

Before using the transmitter, install the battery in the battery 

compartment.

For long life and optimal performance, replace the transmitter 

battery annually with a 12V alkaline battery only.  

Under normal use, an alkaline battery can last up to 12 months.  

Frequent use of the Hi/Lo buttons may reduce battery life. The 

transmitter should operate with as little as 9.0 volts battery power.

IP REMOTE CONTROL INSTALLATION & OPERATION

The transmitter has ON/OFF and HI/LO functions. When you 

press a button on the transmitter, the signal light illuminates to 

verify that a signal is being sent. 

Upon initial use, there may be a delay of three seconds before 

the remote receiver responds. This is part of the system’s design. 

If the signal light does not illuminate, check the position of the 

transmitter’s battery.

MATCHING SECURITY CODES

Each transmitter can use one of 255 security codes. You may 

need to program the module to match the transmitter security 

code upon initial use, or after replacing batteries, or if you need 

to replace the transmitter. 

Slide button on the module to the REMOTE position; 

Press and release the LEARN button on the module to accept 

the transmitter security code and then press any button on the 

transmitter. 

A change in the module’s beeping pattern indicates the 

transmitter’s code has been accepted. Once the module has 

accepted the new transmitter code, the new security code will 

replace the old one.

The microprocessor that controls the security code matching 

procedure is controlled by a timing function. If you are 

unsuccessful in matching the security code on the first 

attempt, wait two minutes before trying again - this allows the 

microprocessor to reset its timer circuitry.   If you are unable to 

match the code after three tries, contact your dealer..

OPERATION

1.  This remote control will operate the AF-4000 gas control 

valves ON/OFF and flame height HI/LO of the main burner.

2.  When the ON button is depressed the transmitter sends a 

RF signal to the module. The module then sends 3 volts of 

power to the internal solenoid. The internal solenoid then 

opens the gas flow to the main burner ON/OFF. The system 

uses a pulse or continuous 3 volts DC power to operate the 

flame HI/LO solenoid motor drive.

3.  The valve will light in the HI setting, then revert to the last 

used setting. If the burner fluctuates between HI and LO, set 

the burner to HI. After five minutes, set the burner to LO.

SPECIFICATIONS

BATTERIES: Transmitter 12V - (A23) Operating Frequency: 

303.8 MHZ FCC ID No.’s: transmitter K9l1001

Canadian ISC ID No.’s: transmitter - 2439 102 728

Summary of Contents for OP36FP32M-3

Page 1: ...flame 3 If odor continues keep away from the appliance and immediately call your gas supplier or fire department WARNING Improper installation adjustment alteration service or maintenance can cause in...

Page 2: ...Dimensions 10 Gas Supply 11 Clearances 12 13 Planning Installation 14 Fireplace Installation Instructions 15 16 Gas Line Connections 16 Millivolt Lighting Instructions OP 36 42 FP3 17 IP Lighting Inst...

Page 3: ...to install fireplace See page 14 3 What accessories are going to be installed See page 5 4 Frame the opening See page 15 5 Install shutoff valve See page 11 6 Install optional drain tray Refer to the...

Page 4: ...r qualified service technician perform an annual inspection and cleaning to prevent malfunction 7 Install logs according to the installation instructions Do not alter log placement from the prescribed...

Page 5: ...2 Inch Bi fold Glass Doors DT36SS 36 Inch Drain Tray Stainless Steel DT42SS 42 Inch Drain Tray Stainless Steel WD36SS 36 Inch Weather Door Stainless Steel WD42SS 42 Inch Weather Door Stainless Steel V...

Page 6: ...M E 136 test Standard Test Method for Behavior of Materials in a Vertical Tube Furnace at 750C are considered non combustible FOR THE HOMEOWNER This fireplace should be inspected before use and at lea...

Page 7: ...torage tank or in iron gas pipes The odorant in escaped gas can adsorb or absorb onto or into walls masonry and other materials and fabrics in a room That will take some of the odorant out of the gas...

Page 8: ...tions to Installer 1 Leave instruction manual with owner 2 Show homeowner the Product Registration Card supplied with fireplace 3 Fill in the Homeowner Reference Information above 4 Show owner how to...

Page 9: ...ndividual firm corporation or company which either in person or through a representative is engaged in and is responsible for a the installation or replacement of gas piping or b the connection instal...

Page 10: ...the box to the gas line opening 2 7 8 2 7 8 L Depth from the front of the box to gas line opening 10 3 8 10 3 8 M Depth from rear of box to gas line opening 8 9 16 8 9 16 Q Distance from floor to fir...

Page 11: ...be resistant to the action of liquefied petroleum gases The installer must check all gas connections for leaks Perform all leak tests with a leak test solution or soap solution Rinse off all solution...

Page 12: ...ance Leave at least 36 inches clearance from the front of the fireplace into the room Ceiling Clearances The ceiling height must not be less than 84 inches from the floor See Figure 9 Mantel Clearance...

Page 13: ...sion Considerations Installing a television above a fireplace has become increasingly popular however the area above any fireplace gets hot and most TV manufacturers recommend against placing their pr...

Page 14: ...erratic flames and main burner outage Erratic flames could also cause soot on logs walls or ceiling Flame outages and sooting are nuisances but pose no safety issues Typical installation may include c...

Page 15: ...l A B C OP36FP 37 41 19 1 4 OP42FP 37 45 19 1 4 Figure 14 Locating Fireplace Place fireplace in framing opening Use the tabs on the side of the fireplace to attach fireplace to framing Different tab l...

Page 16: ...lean it with stainless steel cleaner FIREPLACE INSTALLATION INSTRUCTIONS Install the Hood Failure to install the furnished hood or optional extension hood before the fireplace is used may create a fir...

Page 17: ...t be lighted by hand When lighting the pilot follow these instructions exactly B BEFORE LIGHTING smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heav...

Page 18: ...the appliance and to replace any part of the control system and any gas control which has been under water LIGHTING INSTRUCTIONS TO TURN OFF GAS TO APPLIANCE 1 Locate On Off gas shut off valve and tur...

Page 19: ...gs should be Across the thermopile terminals 400 450 mV with thermostat OFF Across the thermopile terminals 150 250 mV with thermostat ON Across the optional switch wires at the valve less than 30 mV...

Page 20: ...OMER PROVIDED WALL SWITCH RED BLACK NOTICE Do not connect 120V to this unit NOTICE for IP fireplaces only The fireplace may be operated without the remote by connecting the brown control module wires...

Page 21: ...e system s design If the signal light does not illuminate check the position of the transmitter s battery MATCHING SECURITY CODES Each transmitter can use one of 255 security codes You may need to pro...

Page 22: ...rner areas controls piezo covers and grate Inspect and clean burner air intake hole Remove lint or particles with brush Failure to keep air intake hole clean will result in poor combustion For damp or...

Page 23: ...shutoff valve d Thermocouple connection loose at control valve Hand tighten until snug then tighten with wrench 1 4 turn more e Pilot flame not touching thermocouple which allows thermocouple to cool...

Page 24: ...8 38 PARTS LIST Index No Part No Description OP36FP32 OP36FP72 OP42FP32 OP42FP72 1 33848 33848 33849 33849 Face Bottom 2 33851 33851 33852 33852 Face Top 3 33854 33854 33854 33854 Face Side Right 4 33...

Page 25: ...R11979 R11979 Air Shutter Venturi 22 27936 27936 27937 27937 Burner Assembly 23 R7158 R7158 Pilot Nat Thermopile not included 23 R7157 R7157 Pilot LP Thermopile not included 24 R10407 R12005 R10407 R1...

Page 26: ...f purchase and can be ordered by your Service Person or Dealer All parts listed in the Parts List have a Part Number When ordering parts first obtain the Model Number and Serial Number from the rating...

Page 27: ...A bill of sale cancelled check or payment record should be kept to verify purchase date and establish warranty period Ready access to the appliance for service What Is Not Covered Damages that might...

Page 28: ...t Systems Inc 918 Freeburg Ave Belleville IL 62220 If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question please contact...