33858-1-0615
Page 18
FOR YOUR SAFETY, READ BEFORE LIGHTING
WARNING: If you do not follow these instructions exactly, a fire or explosion may result
causing property damage, personal injury or loss of life.
A. BEFORE LIGHTING, smell around the appliance area
for gas. Be sure to smell next to the floor because
some gas in heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch.
• Do not use any phone in your building.
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions. If you can not reach your gas
supplier, call the fire department.
B. Use only your hand to push in or turn the gas control
knob. Never use tools. If the knob will not push in
or turn by hand, don't try to repair it, call a qualified
service technician. Force or attempted repair may
result in a fire or explosion.
C. Do not use this appliance if any part has been under
water. Immediately call a qualified service technician
to inspect the appliance and to replace any part of the
control system and any gas control which has been
under water.
LIGHTING INSTRUCTIONS
TO TURN OFF GAS TO APPLIANCE
1. Locate On/Off gas shut-off valve and turn clockwise to
"OFF." Do not force.
1. STOP! Read the safety information above.
2. Turn gas shut-off valve counterclockwise
to
"ON" position.
3. Wait ten (10) minutes to clear out any gas. Then smell for
gas, including near the floor. If you smell gas, STOP! Follow
"B" in the safety information above on this label. If you do
not smell gas, go to the next step.
4. Find spark and sensor probes.
5. Using the remote control, turn main flame to "ON." If the
burner does not light within 60 seconds, stop and go to
Step 3.
NOTICE:
See Troubleshooting, page 23.
6. If the burner does not stay lit, stop and immediately call a
qualified service technician or gas supplier.
7. If the burner does not operate properly after several tries,
turn the gas control knob clockwise
to "OFF"
and call your service technician or gas supplier.
8. Operation of the gas valve must be controlled by using the
hand-held remote control. Refer to remote instructions for
detailed operation information. See page 21.
OFF
ON
IP LIGHTING INSTRUCTIONS - OP(36,42)FP72
SENSING
PROBE
SPARK PROBE