PRE-INSTALLATION INFORMATION:

Items Required For Installation:

Tools

Building Supplies

Phillips Screwdriver

Hammer

Saw and/or saber saw

Level

Measuring Tape

Electric Drill and Bits

Pliers

Square

Tin Snips

Framing Materials

Wall Finishing Materials

Caulking Material (Noncombustible)

Support Strap supplies

Before You Start:

Plan your installation. Read these instructions and the fireplace installation manual before installing unit and vent system. Set unit in 

place and survey how best to vent the unit. After the vent configuration has been decided, stretch the flex pipe components out, then trim 

off what will not be needed.

Refer to the fireplace installation manual for information on vertical venting requirements. The maximum length of vent when using flex 

venting is 35 feet total. Contact your dealer or distributor for information on flex vent extension kits that may be added to the DVVK-

4FV kit, in order to terminate up to 35 feet. Available extension kits include the DVEK-10 (10’ Flex) or the DVEK-25 (25’ Flex) exten-

sion kits. The extension kits include connection hardware.

Installation of the Vertical Flex Termination Kit

WARNING

Ensure that the venting system exits the structure through the roof and does not terminate less than 12 inches (305mm) above the 

roof.

WARNING

Refer to your fireplace homeowner’s manual for the minimum and maximum venting requirement of your fireplace prior to installa-

tion. Failure to do so may cause a fire hazard.

WARNING

This flexible pipe termination kit is ONLY for vertical terminations.

WARNING

Any horizontal run section must have a 1/4” rise for every one (1) foot of run towards the vent termination. Never allow the vent pipe 

to run downward. This could cause high temperatures and may present a fire hazard. This vertical kit may incorporate two (2) 90 de-

gree bends, but must terminate vertically.

CAUTION

This flex vent kit can be installed either vertically or horizontally off of Direct Vent Series fireplaces but must only terminate verti-

cally.

WARNING

Because of sharp edges, always use gloves when handling the flex vent components.

CAUTION

Vent connections should overlap a minimum of 1” for proper sealing.

CAUTION

Always stretch and secure venting with metal strapping secured with nails (nails and strapping not supplied) to ensure that the flex 

vent runs remain true.

INSTALLATION NOTE:

If space permits, it is generally easier to attach venting in the top vent configuration.

Summary of Contents for DVVK-4FV

Page 1: ...ted before initial use and at least annually by a quali ed eld service person Inspect the external vent cap on a regular basis to make sure that no debris is interfering with the air ow In spect entir...

Page 2: ...e Vertical Flex Termination Kit WARNING Ensure that the venting system exits the structure through the roof and does not terminate less than 12 inches 305mm above the roof WARNING Refer to your replac...

Page 3: ...his opening must be large enough to provide a mini mum 1 air space clearance from the vertical vent pipe to any combustible framing 6 Install the Firestop Thimble assembly to the framed opening in the...

Page 4: ...f cutout opening see step 5 Feed the ex vent end down through the roof opening and restop thimble assembly installed in step 4 14 Secure the roof support assembly to the roof sheathing with at least 4...

Page 5: ...that may be used as an attic insulation shield The collar can be installed around the ex pipe or hard pipe just above the restop thimble This collar will act as a shield to prevent blown in sulation...

Page 6: ...imble Ceiling Straps As Req d Venting Support With Gasket Clamps 7 Dia Adapter Collar 4 Dia Flue Connector Assembly Firestop Thimble Adjustable Storm Collar Use To Keep Keep Insulation Out Of Inlet Ve...

Page 7: ...Ply Alum Flex 7 Diameter by 6 ft MF07ALA2F006 1 5 4 7 x 48 Rigid Pipe Assembly MF100554 1 6 Firestop Thimble Assembly MF100124 1 7 Roof Flashing 0 12 to 6 12 MF100091 1 8 7 Flex Adapter Collar with G...

Page 8: ...21552 0 0506 Page 8 Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 PH 618 233 7420 or 800 851 3153 FAX 618 233 7097 or 800 443 8648 info empirecomfort com www empirecomfort com...

Reviews: