1.  Unpack  vent  components  and  check  all  items  for  shipping 

damage.

2.  For this venting system to operate as designed it is depen-

dent on the use of all parts and procedures detailed in these 

instructions. Failure to follow these instructions may poten-

tially affect the performance of this vent system and the at-

tached appliance.

3.  As per the fireplace manufacturer’s instructions, replace the 

existing 6 5/8” diameter fireplace vent adapter with the 7” 

diameter flex vent fireplace adapter included in the vent kit. 

Install the adapter collar with the screws removed from the 

standard fireplace collar. Refer to the fireplace manual for ad-

ditional information on the vent collar removal and installa-

tion.

4.  Once  the  fireplace  location  has  been  determined,  mark  the 

ceiling where the flex vent will pass through. Cut an opening 

for installation of the firestop thimble assembly. The open-

ing must measure a minimum of 9-1/2” x 9-1/2” square. 

See 

Figure 1.

5.  Next, determine the location for the cutout in the roof open-

ing. This opening must be large enough to provide a mini-

mum 1” air space clearance from the vertical vent pipe to any 

combustible framing.

6.  Install the Firestop/Thimble assembly to the framed opening 

in the ceiling using common nails or screws. 

 

 

Note: 

The  thimble  assembly  is  adjustable  up  or  down  as 

needed within the firestop. It is also designed with a pivoting 

firestop for use with 0 - 3/12 pitch cathedral ceilings.

7.  To begin vent system assembly, first layout all the vent com-

ponents on the floor in the order in which they will be as-

sembled.

8.  Stretch the 4” diameter inner flex flue and 7” diameter outer 

flex vent to the maximum length of 6 foot.

9.  Install  the  spring  spacers  provided  around  the  4”  diameter 

flex flue at 1 foot intervals, then slide the flue pipe with spac-

ers into the 7” diameter outer flex vent pipe. Make sure the 

springs are spaced evenly starting at 12 inches from the fire-

place collar. 

See Figure 2.

NAILS
(4) REQ'D.

THIMBLE

FIRESTOP

CEILING FRAMING

9½” Min.

(241mm)

9½” Min.

(241mm)

NOTE: ADDITIONAL
HOLES FOR ADJUSTING
THIMBLE UP OR DOWN
AS NEEDED

FLEX OUTER

AIR INTAKE PIPE

SPACER SPRINGS

FLEX FLUE PIPE

Figure 1

Figure 2

SPACER SPRINGS

4" FLEX
VENT PIPE

12”

305mm

12”

305mm

12”

305mm

12”

305mm

Step-By-Step Installation For Flex DV Kit

Summary of Contents for DVVK-4FV

Page 1: ...ted before initial use and at least annually by a quali ed eld service person Inspect the external vent cap on a regular basis to make sure that no debris is interfering with the air ow In spect entir...

Page 2: ...e Vertical Flex Termination Kit WARNING Ensure that the venting system exits the structure through the roof and does not terminate less than 12 inches 305mm above the roof WARNING Refer to your replac...

Page 3: ...his opening must be large enough to provide a mini mum 1 air space clearance from the vertical vent pipe to any combustible framing 6 Install the Firestop Thimble assembly to the framed opening in the...

Page 4: ...f cutout opening see step 5 Feed the ex vent end down through the roof opening and restop thimble assembly installed in step 4 14 Secure the roof support assembly to the roof sheathing with at least 4...

Page 5: ...that may be used as an attic insulation shield The collar can be installed around the ex pipe or hard pipe just above the restop thimble This collar will act as a shield to prevent blown in sulation...

Page 6: ...imble Ceiling Straps As Req d Venting Support With Gasket Clamps 7 Dia Adapter Collar 4 Dia Flue Connector Assembly Firestop Thimble Adjustable Storm Collar Use To Keep Keep Insulation Out Of Inlet Ve...

Page 7: ...Ply Alum Flex 7 Diameter by 6 ft MF07ALA2F006 1 5 4 7 x 48 Rigid Pipe Assembly MF100554 1 6 Firestop Thimble Assembly MF100124 1 7 Roof Flashing 0 12 to 6 12 MF100091 1 8 7 Flex Adapter Collar with G...

Page 8: ...21552 0 0506 Page 8 Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 PH 618 233 7420 or 800 851 3153 FAX 618 233 7097 or 800 443 8648 info empirecomfort com www empirecomfort com...

Reviews: