17.  To attach the vent connections at the fireplace, be sure the 7” 

diameter adapter collar has been installed per step #3. Apply 

a bead of silicone sealant to the 4” diameter flex connector, 

then slide the flex pipe adapter collar into the fireplace flue 

collar and secure by installing a minimum of two (2) screws 

through the flue collar and into the adapter. 

See Figure 5.

18.  Apply sealant to the 7” diameter adapter collar, slide outer 

flex vent over the collar, then secure with a 7” diameter band 

clamp. 

See Figure 5.

19.  Once  the  lower  connections  are  made  and  the  flex  pipe  is 

secured with support bands as required (3 foot minimum be-

tween supports) then the roof flashing can be installed.

 See 

Figure 6.

20.  Install  the  roof  flashing,  and  seal  using  common  construc-

tions practices.

21.  An additional storm collar band is provided in kit that may be 

used as an attic insulation shield. The collar can be installed 

around  the  flex  pipe  (or  hard  pipe)  just  above  the  firestop 

thimble. This collar will act as a shield to prevent blown in-

sulation from entering the thimble.

22.  To complete the vent installation, install the vent termination 

cap to the top of the hard vent pipe assembly. Mate up the flue 

and outer telescopes with the hard pipe assembly, then secure 

by installing a minimum of two (2) sheet metal screws into 

the overlapped flanges of the cap and pipe.

23.  Figure  7

 

shows  a  completed  installation  with  components 

identified and other installation information such as heights 

and clearance to combustibles.

BAND CLAMP

APPLY HIGH

TEMPERATURE
SEALANT

(WITH GASKET)

ADAPTER COLLAR

7" DIA. INLET

4" DIA. FLUE

ADAPTER
COLLAR

FLUE PIPE

4" DIA. FLEX

7” DIA. FLEX AIR
INTAKE PIPE

Vent Cap

Storm

Minimum

Clearance to

Combustibles

Collar

Exterior

Roof

Roof

Flashing

Support

Roof

Assembly

7"(178mm) Dia.

Must Extend

7"(178mm) Dia.

Hard Pipe

Through Roof

Flashing

1” (25mm)

Flex

Figure 5

Figure 6

Summary of Contents for DVVK-4FV

Page 1: ...ted before initial use and at least annually by a quali ed eld service person Inspect the external vent cap on a regular basis to make sure that no debris is interfering with the air ow In spect entir...

Page 2: ...e Vertical Flex Termination Kit WARNING Ensure that the venting system exits the structure through the roof and does not terminate less than 12 inches 305mm above the roof WARNING Refer to your replac...

Page 3: ...his opening must be large enough to provide a mini mum 1 air space clearance from the vertical vent pipe to any combustible framing 6 Install the Firestop Thimble assembly to the framed opening in the...

Page 4: ...f cutout opening see step 5 Feed the ex vent end down through the roof opening and restop thimble assembly installed in step 4 14 Secure the roof support assembly to the roof sheathing with at least 4...

Page 5: ...that may be used as an attic insulation shield The collar can be installed around the ex pipe or hard pipe just above the restop thimble This collar will act as a shield to prevent blown in sulation...

Page 6: ...imble Ceiling Straps As Req d Venting Support With Gasket Clamps 7 Dia Adapter Collar 4 Dia Flue Connector Assembly Firestop Thimble Adjustable Storm Collar Use To Keep Keep Insulation Out Of Inlet Ve...

Page 7: ...Ply Alum Flex 7 Diameter by 6 ft MF07ALA2F006 1 5 4 7 x 48 Rigid Pipe Assembly MF100554 1 6 Firestop Thimble Assembly MF100124 1 7 Roof Flashing 0 12 to 6 12 MF100091 1 8 7 Flex Adapter Collar with G...

Page 8: ...21552 0 0506 Page 8 Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 PH 618 233 7420 or 800 851 3153 FAX 618 233 7097 or 800 443 8648 info empirecomfort com www empirecomfort com...

Reviews: