In selecting a location for installation, it is necessary to provide
adequate accessibility clearances for servicing and proper opera-
tion.
Locating and Venting the Direct Vent Fireplace
Clearances: When facing the front of the direct vent fireplace the
minimum clearances to combustible construction (material) are
the following:
Top of appliance (ceiling)
36" (914.4 mm)
Rear Wall
1" (25.4 mm)
Side Wall
6" (152.4 mm)
Heater Corners (45° angle) to Wall
4" (101.6 mm)
Floor
0" (0 mm)
Installation on Rugs and Tile
This appliance must be installed on a flat, solid, continuous surface
(e.g. wood, metal, concrete). This may be the floor, or it may be
raised up on a platform to enhance its visual impact. The continu-
ous surface may be covered with carpeting, vinyl, wood flooring or
other combustible material.
Figure 2
Figure 3
Figure 4
CLEARANCES
6” (153mm)
TO SIDE WALL
6” (153mm) TO
COMBUSTIBLE
MATERIAL
36” (915mm) TO CEILING OR
HORIZONTAL PROJECTION
ABOVE APPLIANCE
NOTE: HEATER INSTALLED AT 45° ANGLE IN CORNER
4” (102mm) HEATER CORNERS TO SIDE WALL
10”
(254mm)
10
”
(254mm)
4”
(102mm)
1” (25.4mm)
TO COMBUSTIBLE MATERIAL