Installing Vent Components (Figure 16 and Figure 17)
Begin the vent system installation by installing the first Simpson
Duravent component, a straight pipe on the top of the appliance, or
rotate the vent elbow to the horizontal position then add horizontal
and vertical pipe lengths and then a horizontal or vertical termination
kit. Elbows can be added where necessary. See Pages 14 through
16 for venting requirements.
Simpson Duravent vent system components lock into place by sliding
the concentric pipe section with four (4) equally spaced interior
beads onto the appliance collar or previously installed component
end with four (4) equally spaced indented sections. When the
internal beads of each starting 6 5/8 inch outer pipe line up, rotate
pipe section clockwise 90° (approximately 3 inches). The vent pipe
is now locked together.
Continue adding components per the pre-planned vent system
configuration. Be certain that each succeeding vent component
is securely fitted and locked into the preceding component in the
vent system.
Figure 16
Figure 17
PIPE LENGTH
(24” MINIMUM)
WALL STRAP
CEILING FIRESTOP
90° ELBOW
90° ELBOW
OR
45° ELBOW
WALL FIRESTOP
HORIZONTAL
TERMINATION
MAXIMUM OF
TWO 90° ELBOWS
VERTICAL
TERMINATION
MAXIMUM OF
THREE 90° ELBOWS
STORM COLLAR
ROOF FLASHING
VENT SYSTEM IDENTIFICATION
Special Venting Components (Simpson Du-
ravent)
See Empire Comfort Systems Inc. Retail Price List
for Simpson Duravent part numbers and pricing
.
PART NAME
"A"
"B"
"C"
6" PIPE
6" (152 mm)
1 1/2" (38 mm)
4 1/2" (114 mm)
9" PIPE
9" (229 mm)
1 1/2" (38 mm)
7 1/2" (191 mm)
12" PIPE
12" (305 mm)
1 1/2" (38 mm)
10 1/2" (267 mm)
24" PIPE
24" (610 mm)
1 1/2" (38 mm)
22 1/2" (572 mm)
36" PIPE
36" (914 mm)
1 1/2" (38 mm)
34 1/2" (876 mm)
48" PIPE
48" (1.220 m)
1 1/2" (38 mm)
46 1/2" (1.18 m)
45° ELBOW
5 1/2" (140 mm) 1 1/2" (38 mm)
---
90° ELBOW
6 1/2" (165 mm) 1 1/2" (38 mm)
5" (127 mm)