No Elbow
B
A
VENTING FIREPLACE - REAR
PIPE LENGTH
(A)
FIREPLACE TO EXTERIOR
WALL (B)
DIMENSIONS IN INCHES
9
9-5/8
12 (1ft)
12-5/8
18 (1ft, 6in)
18-5/8
24 (2ft)
24-5/8
MAXIMUM REAR VENT RUN BY GAS TYPE
PIPE LENGTH
(A)
FIREPLACE TO
EXTERIOR WALL (B)
GAS TYPE
DIMENSIONS IN INCHES
84 (7ft)
84-5/8
NG
36 (3 ft)
36-5/8
LP
Figure 54
VENTING FIREPLACE - TOP
VERTICAL TERMINATION
Vertical Through the Roof Applications
Your Gas Fireplace has been approved for:
a) Vertical installations up to 40 feet in height.
b) Two sets of 45° elbow offsets within these vertical
installations. A vent pipe from 0 to a maximum of 8 feet can
be used between elbows.
c) Wall straps must be used to support offset pipe every 4 feet
This application will require that you first determine the roof pitch
and use the appropriate venting components.
OFFSET CHART
RISE
OFFSET
SIZE
5in X 8in
ELBOW
DEGREES
CHIMNEY
SECTION
OFFSET
INCHES
RISE
INCHES
45°
0in
5-5/8in
15-3/8in
45°
6in
8-7/8in
18-3/8in
45°
9in
10-7/8in
20-5/8in
45°
12in
13in
22-5/8in
45°
24in
21-3/8in
31-1/8in
45°
36in
29-7/8in
39-3/8in
45°
36in
28-7/8in
39-3/8in
45°
48in
38-1/4in
47-7/8in
Figure 53