36092-2-0316
Page 18
WARNING
All wiring should be done by a qualified electrician
and shall be in compliance with all local, city and state
building codes. Before making the electrical connection,
make sure that main power supply is disconnected. The
fireplace, when installed, must be electrically grounded
in accordance with local codes or, in the absence of local
codes, with the National Electrical Code ANSI/NFPA 70
(latest edition). Improper installation of the fireplace can
cause serious injury or death from fire, burns, explosions,
or carbon monoxide poisoning.
A factory installed junction box is located on the outside wall of the
fireplace on the vent side. Wiring must be fed to the junction box
and attached to the stranded wire inside with wire nuts. Connect
white to white, black to black, and ground (green stranded wire) to
the ground screw inside the junction box.
See Figure 16.
JUNCTION BOX WIRING INSTALLATION INSTRUCTIONS
RECEPTACLE BOX
INSIDE FIREPLACE
ELECTRIC
POWER IN
PRE-INSTALLED
CONDUIT TO
RECEPTACLE BOX
STRANDED WIRE
FROM CONDUIT
GROUND SCREW
INSIDE J-BOX
Figure 16