4
Measurement category: CAT III (300 V)
Enclosure: IP20
Dimensions 158 × 75 × 35 mm
Weight: 200 g (batteries included)
Accuracy
Accuracy is defined for the period of one year since calibration of
the device at 18 °C to 28 °C with relative humidity of up to 75 %.
Measurement accuracy is stated as: ± [(% of reading) + (least
significant digit)].
Direct Voltage (DC)
Range
Resolution
Accuracy
200 mV
0.1 mV
+ (0.8 % + 5)
2 V
0.001 V
20 V
0.01 V
200 V
0.1 V
300 V
1 V
+ (1 % + 5)
Input impedance: 10 MΩ
Overload protection: 300 V DC/AC rms
Maximum input voltage: 300 V DC
Alternating Voltage (AC)
Range
Resolution
Accuracy
2 V
0.001 V
+ (1 % + 5)
20 V
0.01 V
200 V
0.1 V
300 V
1 V
+ (1.2 % + 5)
Input impedance: 10 MΩ
Frequency range: 40 Hz to 400 Hz
Overload protection: 300 V DC/AC rms
Note: It is an average value corresponding to a calibrated effective
sine wave.
Max. input voltage: 300 V AC rms
Direct Current (DC)
Range
Resolution
Accuracy
200 µA
0.1 µA
+ (1.2 % + 5)
2 000 µA
1 µA
20 mA
0.01 mA
200 mA
0.1 mA
2 A
0.001 A
+ (2 % + 10)
10 A
0.01 A
Overload protection:
µA and mA range: F 250 mA L 300 V fuse
10 A range: F 10 A L 300 V fuse
Maximum input current:
INPUT socket max. 200 mA
10 A socket max. 10 A
(when measuring current higher than 2 A, do not measure for
longer than 15 seconds and further measurements can only be
repeated after 15 minutes)
Alternating Current (AC)
Range
Resolution
Accuracy
200 µA
0.1 µA
+ (1.5 % + 5)
2 000 µA
1 µA
20 mA
0.01 mA
200 mA
0.1 mA
2 A
0.001 A
+ (3 % + 10)
10 A
0.01 A
Overload protection:
µA and mA range: F 250 mA L 300 V fuse
10 A range: F 10 A L 300 V fuse
Maximum input current:
INPUT socket max. 200 mA
10 A socket max. 10 A
(when measuring current higher than 2 A, do not measure for
longer than 15 seconds and further measurements can only be
repeated after 15 minutes)
Frequency range: 40 Hz to 400 Hz
Note: It is an average value corresponding to a calibrated effective
sine wave.
Direct Current
(Measurement Using a Clamp – Optional
Accessory to MD-420)
Range
Resolution
Accuracy
measurement
200 A
0.1 mV/0.1 A
+ (1.2 % + 5)
measurement
1 000 A
1 mV/1 A
Maximum input voltage: 200 mV DC
Alternating Current
(Measurement Using a Clamp –
Optional Accessory to MD-420)
Range
Resolution
Accuracy
measurement
200 A
0.1 mV/0.1 A
+ (1.5 % + 5)
measurement
1 000 A
1 mV/1 A
Maximum input voltage: 200 mV AC
Frequency range: 40 Hz to 400 Hz
Note: It is an average value corresponding to a calibrated effective
sine wave.
Resistance
Range
Resolution
Accuracy
200 Ω
0.1 Ω
+ (1.2 % + 5)
2 kΩ
0.001 kΩ
+ (1 % + 5)
20 kΩ
0.01 kΩ
200 kΩ
0.1 kΩ
2 MΩ
0.001 MΩ
+ (1.2 % + 5)
20 MΩ
0.01 MΩ
+ (1.5 % + 5)
Open-circuit voltage: 1 V
Overload protection: 300 V DC/AC rms
Temperature
Range
Resolu-
tion
Accuracy
-20 °C ~ 1 000 °C
1 °C
-20 °C ~ 0 °C: + (5 % + 4)
0 °C ~ 400 °C: + (1 % + 3)
400 °C ~ 1 000 °C: + (2 % + 3)
0 °F ~ 1 800 °F
1 °F
0 °F ~ 50 °F: + (5 % + 8)
50 °F ~ 750 °F: + (1 % + 6)
750 °F ~ 1 800 °F: + (2 % + 6)
Capacity
Range
Resolution
Accuracy
20 nF
0.01 nF
+ (8 % + 10)
200 nF
0.1 nF
+ (5 % + 5)
2 µF
0.001 µF
20 µF
0.01 µF
200 µF
0.1 µF
1,000 µF
1 µF
+ (8 % + 10)
Open-circuit voltage: 1 V
Transistor hFE Test
Range
hFE
Testing cur-
rent
Testing volt-
age
PNP and NPN
0 ~ 1 000
Ib ≈ 2 µA
Vce ≈ 1 V