4.3
Main display
The transmitter displays one or two primary measurement values, up to six secondary
measurement values, a fault and warning banner, alarm relay flags, and a digital
communications icon.
4.3.1
Process measurements
If two signal boards are installed, the transmitter displays two process variables. If one
signal board is installed with one sensor, the transmitter displays one process variable and
process temperature.
The upper display area shows the Sensor 1 process reading. The center display area shows
the Sensor 2 process reading. For dual conductivity, you can assign the upper and center
display areas to different process variables.
For single input configurations, the upper display area shows the live process variable, and
you can assign the center display area to Temperature or blank.
4.3.2
Secondary values
The display quadrants at the bottom half of the screen show up to six secondary values.
You can program all six secondary value positions to any display parameter available.
4.4
Menu system
The menu system is similar to a computer. Press the
ENTER/MENU
key at any time to open
the top-level menu including Calibration, Hold, Programming, Display, Data, and HART
®
functions. To find a menu item, use the directional navigation keys to highlight a menu
item. Press
ENTER/MENU
, direct the cursor to the desired operation, and follow the screen
prompts. Press the
BACK
screen control available on some menu screens to revert to the
immediate previous menu screen. Press the
EXIT
key to return to the previous hierarchical
menu level.
Fault and Warning banners
If the transmitter detects a problem with itself or the sensor, the
Fault
banner (red) and/or
Warning
banner (yellow) appears at the bottom of the main display. A fault requires
immediate attention. A warning indicates a problematic condition or an impending
failure. For detailed troubleshooting assistance, press
INFO
.
Reference Manual
Display and operate
00809-0100-3565
July 2020
Rosemount T56
33
Summary of Contents for Rosemount Clarity II T56
Page 1: ...Reference Manual 00809 0100 3565 Rev AB July 2020 Rosemount Clarity II T56 Turbidmeter ...
Page 4: ...4 ...
Page 30: ...Wire Reference Manual July 2020 00809 0100 3565 30 Emerson com Rosemount ...
Page 34: ...Display and operate Reference Manual July 2020 00809 0100 3565 34 Emerson com Rosemount ...
Page 44: ...Program turbidity Reference Manual July 2020 00809 0100 3565 44 Emerson com Rosemount ...
Page 48: ...Calibrate Reference Manual July 2020 00809 0100 3565 48 Emerson com Rosemount ...
Page 56: ...Maintenance Reference Manual July 2020 00809 0100 3565 56 Emerson com Rosemount ...