Reference Manual
300520EN, Rev AA
November 2009
3-37
Rosemount 5900 Series
Section 3. Installation
5. Place a gasket (customer supplied) on
the Mounting Flange.
6. Carefully fit the Pipe Cone into the still
pipe and tighten the Closing onto the
Mounting Flange (customer supplied
screws and nuts).
7. Direct the Closing so that the marking
hole aligns with the notch or mark on
the pipe flange.
8. The tank is now sealed and can, as far
as Rosemount Tank Gauging
equipment is concerned, be
pressurized
9. Remove the yellow protection cap.
Do not remove the rubber cone.
Closing
Mounting
Flange
Notch indicating the
direction of the
Reference Pin
Marking
hole
Align!
Reference pin
Do not remove
this cone!
Protection cap