7.9.5
Logging measurement data
By using the Log Device Registers function in the Rosemount Radar Master software, you
can log Input and Holding registers over time. It is possible to choose from different pre-
defined sets of registers. This function is useful for verifying that the transmitter works
properly.
Procedure
1. In Rosemount Radar Master, select
Tools
→
Log Device Registers.
2. In the
Log Registers
window, select the
Browse
button.
3. Type your desired file name.
4. Browse to the desired directory, and then select
Save
.
5. Select the
Select Register
button.
6. Select the desired registers to be logged. There are three options available:
Option
Description
Standard Logs the most common registers and are often sufficient.
Service
If you experience problems with your device you may be asked to send
a Service Log to our service department.
Custom Define your own set of parameters to log.
7. If
Custom
is selected, then:
a) Select
Read only (Input)
or
Read/Write (Holding)
.
b) In the
Register Group
list, select select the desired register group.
Reference Manual
Service and troubleshooting
00809-0100-4530
April 2019
Reference Manual
213