HART Communicator
October 2016
Reference Manual
00809-0100-4808, Rev DA
61
HART Communicator
FIGURE C-1. HART Communicator Typical Abbreviated Menu Tree
1 DEVICE
SETUP
2 PV
3 AO
4 LRV
5 URV
Online
Menu
1 Pressure
2 Percent Range
3 Analog Output
4 Sensor
Temperature
1 TEST DEVICE
2 Loop Test
3 CALIBRATION
1 Self Test
2 Status
1 RERANGE
2 TRIM ANALOG
OUTPUT
3 SENSOR TRIM
7 METER OPTS.
1 SENSORS
2 SIGNAL
CONDITION
3 OUTPUT
CONDITION
4 DEVICE
INFORMATION
4 RECALL FACTORY
TRIM
1 Keypad Input
2 Apply Values
1 Digital-to-Analog Trim
2 Scaled D/A Trim
1 Zero Trim
2 Lower Sensor Trim
3 Upper Sensor Trim
4 Sensor Trim
Calibration Type
5 Sensor Trim Points
1 Sensor Trim
2 Analog Output Trim
1 Keypad Input
2 Apply Values
1 Date
2 Descriptor
3 Message
4 Write Protect
1 Tag
2 Unit
3 RANGE VALUES
4 DEVICE INFO
5 Transfer
Function
6 Damp
1 Meter Type
2 CUSTOM METER
SETUP
1 PRESSURE
SENSOR
2 TEMP SENSOR
1 Sensor Temp
2 Temperature Unit
1 Sel Dec Pt Pos
2 CM Upper Value
3 CM Lower Value
4 CM Units
5 CM xfer function
1 PROCESS VARIABLE
2 SENSOR SERVICE
3 Unit
1 Pressure
2 % Range
3 Sensor Temp
1 SENSOR
TRIM
2 Recall
Factory
Trim
1 Zero Trim
2 Lower Sensor
Trim
3 Upper Sensor
Trim
4 Sensor Trim
Calibration
Type
5 Sensor Trim
Points
1 PROCESS
VARIABLE
2 RANGE VALUES
3 Unit
4 Transfer Func
5 Damp
6 Snsr Temp Unit
7 ALM/SAT
LEVELS
1 PROCESS
VARIABLES
2 ANALOG
OUTPUT
3 HART OUTPUT
4 METER
OPTIONS
1 FIELD DEVICE
INFO
2 SENSOR INFO
3 Self Test
4 DIAPHRAGM
SEALS INFO
1 Pressure
2 % Range
3 Snsr Temp
1 Keypad Input
2 Apply Values
1 High Alarm
2 Low Alarm
3 High Saturation
4 Low Saturation
5 AO Alarm Type
6 Alarm/Sat Type
1 Pressure
2 % Range
3 Analog Output
4 Sensor Temp
1 Loop Test
2 Digital-to-Analog Trim
3 Scaled D/A Trim
4 AO Alarm Type
1 Poll Address
2 Nos. of Req. Pream.
3 Burst Mode
4 Burst Option
1 Meter Type
2 CUSTOM METER
SETUP
3 Custom Meter Value
1 Measurement Type
2 Mod. Config. Type
3 Isolator Material
4 Fill Type
5 Proc. Conn. Type
6 Proc. Conn. Material
7 O-Ring Material
8 Drain/Vent Material
1 Sel. Dec. Pt. Pos.
2 CM Upper Value
3 CM Lower Value
4 CM Units
5 CM xfer function
1 Tag
2 Date
3 Descriptor
4 Message
5 Model
6 Write Protect
7 Local Keys
8 REVISION #S
9 Final Assy #
10 Device ID
11 Distributor
1 Univ. Rev.
2 Fid. Dev.
Rev.
3 S/W Rev.
1 # of Diaphr. Seals
2 Diaphr. Seal Type
3 Diaphr. Seal Fill
4 Diaphr. Material
“3051” will appear in the upper left of the
communicator screen when this menu tree is valid.
1 PROCESS
VARIABLE
2 DIAGNOSTICS
AND SERVICE
3 BASIC SETUP
4 DETAILED
SETUP
5 Review