75
Reference Manual
00809-0100-4108, Rev BA
Appendix A: Specifications and Reference Data
March 2014
Appendix A: Specifications and Reference Data
A.3
Physical specifications
Electrical connections
1
/
2
–14 NPT, M20
1.5 (CM20), or
G
1
/
2
female (PF
1
/
2
female) conduit entry
Process connections
1
/
2
–14 NPT female, DIN 16288 G
1
/
2
male, RC
1
/
2
female
(PT
1
/
2
female), M20
1.5 (CM20) male
A.3.1
Process-wetted parts
Isolating diaphragm
316L SST (UNS S31603), Alloy C-276 (UNS N10276)
Process connector
316L stainless steel CF-3M (Cast version of 316L SST, material per ASTM_A743) or Alloy C-276
A.3.2
Non-wetted parts
Electronics housing
Low-copper aluminum, NEMA 4X, IP65, IP67, CSA enclosure Type 4X
Paint for aluminum housing
Polyurethane
Cover O-rings
Buna-N
Fill fluid
Silicone or inert fill
Weight
Output Code S and N: Approximately 2.44 lb (1,11 kg)
Standard operation
Output code
Linear output
Fail high
Fail low
S
3.9
I
20.8
I
21.75 mA
I
3.75 mA
N
0.97
V
5.2
V
5.4 V
V
0.95 V
NAMUR-compliant operation
Output code
Linear output
Fail high
Fail low
S
3.8
I
20.5
I
22.5 mA
I
3.6 mA