PACMotion™ PSD Installation and User Manual
Section 4
GFK-3168A
September 2020
Technical Description and Data
23
takes place as described under 1. (above) for the drive that has the lowest switch-off threshold
(resulting from tolerances).
Note: Observe the regeneration time (some minutes) after full load with peak regen power.
4.14.3
Technical data for IC830DPzzz06
Technical data for the regen circuit depends on the drive type and the mains voltage. Supply
voltages, capacitances, and switch-on voltages are all nominal values.
Brake circuit
Supply voltage
120 V / 240 V
Type
Rated data
Units
IC830DPzzz06
all types
Switch-on threshold of regen circuit
V
380
Overvoltage limit
V
420
Maximum regen duty cycle
%
15*
Type
Rated data
Units
120 V / 240 V
IC830DP00106
External regen resistor
Ohm
33
Maximum continuous regen power,
external resistor
kW
0.48
Peak regen power, external (1s)
kW
5.4
Absorption energy in capacitors (+/-
20%)
Ws
60 / 20
DC Bus Capacitance
µF
940
IC830DP00306
External regen resistor
Ohm
33
Maximum continuous regen power,
external resistor
kW
0.77
Peak regen power, external (1s)
kW
5.4
Absorption energy in capacitors (+/-
20%)
Ws
60 / 20
DC Bus Capacitance
µF
940
IC830DP00606
External regen resistor
Ohm
33
Maximum continuous regen power,
external resistor
kW
1.5
Peak regen power, external resistor (1s)
kW
5.4
Absorption energy in capacitors (+/-
20%)
Ws
60 / 20
DC Bus Capacitance
µF
940
IC830DP01206
Internal regen resistor
Ohm
15
Continuous power, internal resistor
W
100
Peak regen power, internal resistor
(0.5s)
kW
11.7
External regen resistor
Ohm
15
Maximum continuous regen power,
external resistor
kW
3
Peak regen power, external resistor (1s)
kW
5.4
Absorption energy in capacitors (+/-
20%)
Ws
160 / 55
DC Bus Capacitance
µF
2460
IC830DP02406
Internal regen resistor
Ohm
8
Continuous power, internal resistor
W
200