G3
Series
PROFIBUS
‐
DP
Technical
Manual
Page
53
TDG3PTTM1-2EN
02/09
Subject to change without notice
www.numatics.com/g3
Manifold and I/O Data Sizing Worksheet
Step
1
: Choose corresponding
Input and Output values based on the chosen “Valve Side Output Options” and place the values in the boxes
labeled, “Valve Side Byte Requirements” at the bottom of the page
2
: Choose up to sixteen modules to be included on the discrete I/O side of the manifold (including distributed modules) and place sum of
the corresponding input bytes and output bytes in the boxes labeled, “Discrete Side Byte Requirements” at the bottom of the page.
3
: Add the input bytes and output bytes values from the boxes labeled “Discrete Side Byte Requirements” and “Valve Side Byte
Requirements” and place total in the boxes labeled “Total I/O Bytes for Manifold. This is the total input and output byte count values
required for the configured manifold.
Valve Side
Step
Valve Side Output Options
(selected via GSD file)
Input Bytes
Output Bytes
Up to 8 Solenoid Coils
0
1
Up to 16 Solenoid Coils
0
2
Up to 24 Solenoid Coils
0
3
1
Up to 32 Solenoid Coils
0
4
Digital Modules
Step
Module Part Number
Description
Input Bytes
Output Bytes
240-203/204
16 Inputs - Terminal Strip
2
0
240-205/209
16 Inputs - 8 x M12
2
0
240-206/210
8 Inputs - 8 x M12
1
0
240-207
16 Outputs - 8 x M12
0
2
240-208
8 Outputs - 8 x M12
0
1
240-211
8 Inputs / 8 Outputs - 8 x M12
1
1
2
240-241
Distributed Sub-Bus Valve Module
0
1, 2, 3 or 4
Analog Modules
Step
Module Part Number
Description
Input Bytes
Output Bytes
240-212/214
4 Inputs – 4 x M12
8
0
2
240-213/215
2 Inputs/ 2 Outputs – 4 x M12
4
4
Total Input/Output Size Calculation
Step
Module Position
(includes distributed modules)
Module Part Number
Input Bytes
Output Bytes
1
st
2
nd
3
rd
4
th
5
th
6
th
7
th
8
th
9
th
10
th
11
th
12
th
13
th
14
th
15
th
16
th
2
Discrete Side Byte Requirements:
1
Valve Side Byte Requirements:
3
Total I/O Bytes for Manifold