19
emersonfans.com
Please contact 1-800-654-3545 for further assistance
ETL Model No.: CF790
HOT
BLACK
SW405
FAN/LIGHT
WALL
CONTROL
TRAVELER
WIRE
B
L
K
B
L
K
LOAD
BLACK
GROUND
NEUTRAL
EMERSON
®
EMERSON
®
RECEIVER LOCATED
WITHIN THE CEILING
COVER
SECOND
SW405 WALL
CONTROL
PURCHASED
SEPARATELY
HI
MED
LOW
FAN OFF
LIGHT
ON
OFF
HI
MED
LOW
FAN OFF
LIGHT
ON
OFF
3-WAY
INSTALLATION
(One fan controlled by two different SW405 wall
controls) (See Figures 31 and 32.)
7.9
Disconnect electrical power to the branch circuit at the
circuit breaker or fuse box before attempting to install
the ceiling fan SW405 wall control into the outlet box.
7.10
At all wall box locations remove faceplates and screws
from existing controls. Pull controls out from wall boxes
and determine which wall box contains the “hot” lead
and which wall box contains the “load” wire. Also,
identify traveler wires which are common to both wall
boxes. Disconnect wires from existing controls only.
Do not attempt to disconnect any wires not already
connected to existing controls.
7.11
Before installing the SW405 wall control, place the
SW405 wall control in “OFF” mode by pushing
“ON/OFF” switch to the “OFF” position.
7.12
Install a SW405 wall control in the wall box containing
the “hot” wire first. Connect the black wire of the SW405
wall control to the “hot” wire. Securely connect the wires
with wire connectors supplied.
7.13
Connect the other black wire of the SW405 wall control
to both remaining traveler wires in the wall box and
secure with wire connector supplied.
Figure 31
Turning off wall switch is not sufficient. To avoid
possible electrical shock, be sure electricity is turned
off at the main fuse or circuit breaker box before
wiring. All wiring must be in accordance with National
and Local codes and the ceiling fan must be properly
grounded as a precaution against possible electrical
shock.
WARNING
!
Do not connect any neutral (white) wire to this control.
Incorrect wiring will damage this control.
WARNING
!
7. Wall Control Installation
(Continued)