6
ETL Model No.: CF790
3. Ceiling Fan Assembly
(Continued)
MOTOR
COUPLING
4.5"
DOWNROD
CLEVIS
PIN
HAIRPIN
CLIP
HAIRPIN
CLIP
CLEVIS
PIN
LOOSEN
SETSCREWS (2)
Figure 3
3.4
Loosen the two setscrews in the motor coupling.
Place the 4.5” downrod into the motor coupling, aligning
the clevis pin holes in the downrod with the holes in the
motor coupling (Figure 3).
The clevis pin must go through the holes in the motor
coupling and the holes in the downrod.
Be sure to push the straight leg of the hairpin clip
through the hole near the end of the clevis pin until the
curved portion of the hairpin clip snaps around the
clevis pin.
The hairpin clip must be properly installed to prevent
the clevis pin from working loose.
Pull on the downrod to make sure the clevis pin is
properly installed.
4.5" DOWNROD
MOTOR
COUPLING
RETIGHTEN
SETSCREW
RETIGHTEN
SETSCREW
Figure 4
4.5" DOWNROD
COUPLING
COVER
GROMMET
Figure 5
3.6
Make sure the grommet is properly installed in the
coupling cover then slide the coupling cover on the
downrod until it rests on the motor housing (Figure 5).
It is critical that the clevis pin in the motor coupling is
properly installed. Failure to verify that the pin is
properly installed could result in the fan falling.
WARNING
!
3.5
While pulling up on the 4.5” downrod, retighten the two
setscrews (previously loosened) in the motor coupling
to secure the downrod into place (Figure 4).
NOTE: The setscrews must be properly installed as
described above, or fan wobble could result.
It is critical that the setscrews are securely tightened.
Failure to verify that the setscrews are properly
installed could result in the fan falling.
WARNING
!