100-214-294 REV. 05
43
6.5.1
CPXH Series Explanation of Controls
Figure 6.4
CPXH Series Controls
Table 6.15 CPXH Series explanation of controls.
Control
Function
Main
Power
Switch
This switch is located on the back of the unit, next to the power cord
receptacle.
• Press the on side to power on the unit
• Press the off side to power off the unit. When operating the unit, normally leave
the Main Power switch in the on position, and use the On/Standby key to switch
between the operating state and standby state
On/Standby
When the Main Power switch on the rear panel is in the on position, press
to power on/off the unit.
Up/Down Keys
Press to increase/decrease ultrasonic or degassing cycle time (hold for
quick increments/decrements).
Time values are circular, pressing Up key from 99 minutes takes you to 1
minutes. Pressing Down key from 1 minutes takes you to 99 minutes.
If the Fn key was pressed, use the Up/Down keys to adjust function
settings.
Heat
Press to turn heater on/off.
Heater will shut off when set temperature is attained.