58
AXIMA 2000/4000 Installation Manual
Components of the Direct Wiring Option
Quantities of the components required for the direct wiring option
depend on the number of I/O used.
For example:
For the full use of 32 expanded inputs and 32 expanded outputs, the
required quantities are:
(1) AXIMA 2000/4000 controller
(2) STI-32 or STI-50 for digital I/O
(2) Connectorized ribbon cables (50 pin) (P/N XIOC-XXX)
Dimensions of STI-50 and STI-32 Components
Figure 48
STI-50 and STI-32 Components
I/O Setup and Wiring
Using the direct wiring option, the inputs and outputs can be wired
directly to the STI-32 (sourcing only) or STI-50 (sinking or sourcing)
using ribbon cables.
To use the direct wiring option, you must meet the following criteria:
For Inputs:
Electrical specifications of 24 VDC and a minimum of 11 mA of
current.
STI-50
STI-32
5.28
(134.11)
3.00
(76.2)
7.423
(188.54)
3.53
(89.76)
Dimensions in () are millimeters