47
Connections and Cabling
I/O Power Supply
The AXIMA requires a customer supplied I/O power supply, usually
24 volts. This power supply must be connected to the 24V ±
terminals. The 24 volts are protected against reverse polarity if the
polarity is reversed the 24 volts fuse blows. The fuse is located under
the front access panel. This supply is the "machine side" of the inputs
and outputs and also provides power for the Enable Drive relay coils.
The system is designed to operate from a 24 VDC power supply but
will function with between 18 and 30 VDC.
Figure 39
I/O Power Supply Location on the Front Panel of the
AXIMA 2000/4000
NOTE:
For situations where all 16 inputs, 12 outputs at full load
and 4 relays are being used simultaneously, your power
supply must supply at least 2.5 amps @ 24 volts.
Each input requires 12 mA @ 24 VDC (5 mA @ 10 VDC).
Each output can source up to 150 mA to drive a load.
+
-
24V
2
A
FUSE F103
2 AMPS