Rosemount Model 8800C Vortex Flowmeter
D-6
E
Message
Description
XMTR still busy.
Flowmeter is running a computational or diagnostic routine and
cannot respond to the Model 268 instructions. Press the PREVIOUS
FUNCTION key to cancel.
XXXX=YYYY ERR–Illegal value.
Unacceptable value entered.
XXXX=YYYY ERR–
Out of range.
The difference between LRV and URV is greater than the maximum
span allowed by the flowmeter. Enter a new value.
XXXX=YYYY ERR–Span too small.
The difference between LRV and URV is less than the minimum span
allowed by the flowmeter. Enter a new value.
XXXX=YYYY ERR–Value was too hi.
See instructions for the selected parameter. Enter a new value that
is acceptable.
XXXX=YYYY ERR–Value was too lo.
See instructions for the selected parameter. Enter a new value that
is acceptable.
XXXX=YYYY ERR–LRV too hi.
LRV was set to a value above the URL. Enter a new value.
XXXX=YYYY ERR–LRV too lo
LRV was set to a value above the LRL Enter a new value.
XXXX=YYYY ERR–
LRV and URV out limits.
Both the LRV and URV were outside the sensor’s range limits. Enter
a new value.
XXXX=YYYY ERR–URV too hi.
URV was set to a value above the URL. Enter a new value.
XXXX=YYYY ERR–URV too lo.
URV was set to a value below the LRL. Enter a new value.
XXXX=YYYY ERR–268 data err.
Flowmeter cannot interpret a Model 268 inquiry. Make note of
conditions and keystrokes leading to failure, and contact Rosemount
Service Center.
268 Failure–No. 1.
268 Failure–No. 2.
Model 268 has detected bug in its software. Make note of conditions
and keystrokes leading to failure, and contact Rosemount Service
Center.
268 Test: FAIL.
Model 268 is not functioning properly. Turn OFF and contact
Rosemount Service Center.
Summary of Contents for 8800A
Page 1: ...Model 8800C and Model 8800A Smart Vortex Flowmeter 00809 0100 4003 English Rev JA ...
Page 2: ......
Page 4: ...Rosemount Model 8800C Vortex Flowmeter ...
Page 8: ...Rosemount Model 8800C Smart Vortex Flowmeter 4 ...
Page 10: ...Rosemount Model 8800C Vortex Flowmeter 1 2 ...
Page 48: ...Rosemount Model 8800C Vortex Flowmeter 2 38 ...
Page 74: ...Rosemount Model 8800C Vortex Flowmeter 3 26 ...
Page 102: ...Rosemount Model 8800C Vortex Flowmeter 4 28 ...
Page 128: ...Rosemount Model 8800C Vortex Flowmeter B 2 ...
Page 129: ...B 3 Approvals ...
Page 130: ...Rosemount Model 8800C Vortex Flowmeter B 4 ...
Page 131: ...B 5 Approvals ...
Page 132: ...Rosemount Model 8800C Vortex Flowmeter B 6 ...
Page 133: ...Appendix C 1 Appendix C HART Communicator Connections and Hardware page C 6 ...
Page 142: ...Rosemount Model 8800C Vortex Flowmeter C 10 ...
Page 159: ......