A-7
Reference Data
Gas and Steam—
for Reynolds Numbers over 15,000
NOTE
For
1
/
2
-in. through 4-in. (15 mm through 100 mm) line sizes, as the
Reynolds number decreases below the stated limit to 10000, the
positive limit of the accuracy error band will increase to 2.1% for the
pulse output. Example: +2.1% to –0.65% for liquids.
Repeatability
± 0.1% of actual flow rate
Stability
±0.1% of rate over one year
Process Temperature Effect
Automatic K-factor correction with user-entered process temperature
Table A-5 indicates the percent change in K-factor per 100 °F (50 °C) in
process temperature from reference temperature of 77 °F (25 °C) for
direct pulse, or user-entered process temperature.
Ambient Temperature Effect
Digital and Pulse Outputs
No effect
Analog Output
±0.1% of span from –40 to 185 °F (–40 to 85 °C)
Digital and Pulse Output
±1.35% of rate
Analog Output
Same as pulse output plus an additional 0.025% of span
Accuracy limitations for gas and steam:
- for
1
/
2
- and 1-in. (DN 15 and DN 25):
max velocity of 220 ft/s (67.06 m/s)
- for Dual-style meters (all sizes):
max velocity of 100 ft/s (30.5 m/s)
Table A-5. Process Temperature Effect
Material
Percent Change in K-Factor per 100 °F (50 °C)
316L @ < 77 °F (25 °C)
+ 0.23 (+ 0,20)
316L @ > 77 °F (25 °C)
- 0.27 (- 0,24)
Hastelloy
®
C @ < 77 °F (25 °C)
+ 0.22 (+ 0,20)
Hastelloy
®
C @ > 77 °F (25 °C)
- 0.22 (- 0,20)
Summary of Contents for 8800A
Page 1: ...Model 8800C and Model 8800A Smart Vortex Flowmeter 00809 0100 4003 English Rev JA ...
Page 2: ......
Page 4: ...Rosemount Model 8800C Vortex Flowmeter ...
Page 8: ...Rosemount Model 8800C Smart Vortex Flowmeter 4 ...
Page 10: ...Rosemount Model 8800C Vortex Flowmeter 1 2 ...
Page 48: ...Rosemount Model 8800C Vortex Flowmeter 2 38 ...
Page 74: ...Rosemount Model 8800C Vortex Flowmeter 3 26 ...
Page 102: ...Rosemount Model 8800C Vortex Flowmeter 4 28 ...
Page 128: ...Rosemount Model 8800C Vortex Flowmeter B 2 ...
Page 129: ...B 3 Approvals ...
Page 130: ...Rosemount Model 8800C Vortex Flowmeter B 4 ...
Page 131: ...B 5 Approvals ...
Page 132: ...Rosemount Model 8800C Vortex Flowmeter B 6 ...
Page 133: ...Appendix C 1 Appendix C HART Communicator Connections and Hardware page C 6 ...
Page 142: ...Rosemount Model 8800C Vortex Flowmeter C 10 ...
Page 159: ......