EES-101 Series Ultrasonic Flowmeter
Revision: 3.0.1
Page 59 of 65
Step4. Transducers type(Note: display option error)
Press the
keys to enter the
window M23, press the
or
key to
select transducer type, and press the
key
to confirm.
1. Plug
-
in-W211
(W type insertion
transducer).
Step5. Transducer mounting methods
Press the
keys to enter the
window M24, press the
key, press the
or
key to select transducer-mounting
method, and press the
key to confirm.
Choose according to the pipes on site.
Step6. Adjust Transducer spacing
Press the
keys to enter the
window M25, accurately install the transducer
according to the displayed transducer mounting
spacing and the selected mounting method
(Refer to Installing the Transducers in this
chapter).
Step7. Display measurement result
Press the
keys to enter the
window M01.
About other setup,please refer to the related
information in the manual.
Menu
2
3
^
^
Enter
Transducer Type [23
2. Plug-in-W211
Menu
2
4
Enter
^
^
Enter
Transducer Mounting
1. Z
Menu
2
5
Transducer Spacing
192.68 mm
Menu
0
1
Flow 0.1129m3/h *R
Vel
1.0415m/s