EES-101 Series Ultrasonic Flowmeter
Revision: 3.0.1
Page 45 of 65
return "OK" when success.
READSE
Read system error type
1. Read command;
2. Return error code and error prompt string.
RUNIT
Set whether to return unit when reading
data such as flow
1. Write command with parameters, such as
RUNIT1;
2. The setting of parameter 0 is return data
without unit, and the setting of parameter
non-0 is return data with unit (default);
3. The settings will be saved;
4. Return "set error" when setting error, return
"memory error" when storage error, and
return "OK" when success.
SCH
Set the corresponding value of 20mA
1. Write command with parameters, for
example: SCH100;
2. The setting value changes according to the
change of the unit;
3. The settings will be saved;
4. Return "set error" when setting error, return
"memory error" when storage error, and
return "OK" when success;
5. Remarks: when 4-20mA is configured into
flow output, this setting is the upper limit of
the flow. When flow velocity outputs, this
setting is the upper limit of the flow velocity.
SCL
Set the corresponding value of 4mA
1. Write command with parameters, for
example: SCL0;
2. The setting value changes according to the
change of the unit;
3. The settings will be saved;
4. Return "set error" when setting error, return
"memory error" when storage error, and
return "OK" when success;
5. Remarks: when 4-20mA is configured into
flow output, this setting is the lower limit of
the flow. When flow velocity outputs, this
setting is the lower limit of the flow velocity.
SDATE
Set date
1. Write command with parameters, such as
SDATE2019-06-27;
2. Setting error returns "set error" and "OK"
successfully.
SDID
Set internet address
1. Write command with parameters, such as
SDID88;
2. The value can be set as 1-247, and the
default value is 88;
3. Return "set error" when setting error, return
"memory error" when storage error, and
return "OK" when success.
SED
Set the outside diameter
1. Write command with parameters;