EES-101 Series Ultrasonic Flowmeter
Revision: 3.0.1
Page 44 of 65
DID
Return identification code of instrument
(address code)
1.
Read command;
2.
The return value is expressed in decimal.
DL
Return signal intensity
1.
Read command;
2.
The format of return value:
UP:dd.d,DN:dd.d,Q=dd
DT
Current date and time
1.
Read command;
2.
The format of return data:
yy-mm-dd,hh:mm:ss(cr)
ESN
Return electronic serial number
1.
Read command;
2.
The format of return data: ddddddd(cr)(lf)
Note: 2
E+
Instantaneous heating Energy
1.
Read command
;
2.
The format of return data:
±
dddddddE
±
dd
E-
Instantaneous cooling Energy
1.
Read command
;
2.
The format of return data:
±
dddddddE
±
dd
DIE+
Accumulated heating energy
1.Read command
;
2. When the value exceeds 10^8, the accuracy
will be lost, and the displayed data shall
prevail;
;
3. The format of return data
:
±
dddddddE
±
dd
DIE-
Accumulated cooling energy
1.Read command
;
2. When the value exceeds 10^8, the accuracy
will be lost, and the displayed data shall
prevail;
;
3. The format of return data:
±
dddddddE
±
dd
DIE
Accumulated energy
1.Read command
;
2. When the value exceeds 10^8, the accuracy
will be lost, and the displayed data shall
prevail;
;
3. The format of return data:
±
dddddddE
±
dd
MPAS
ModBus is compatible with previous
device switch
1. Write command with parameters, such as
MPAS1;
2. Parameter 0 indicates incompatibility
(default), and parameter non-0 indicates
compatibility;
3. It is compatible with the numerical data
type in Modbus protocol of previous models,
and the string data type is not compatible with
the device except the serial number;
4. The settings will be saved;
5. Return "set error" when setting error, return
"memory error" when storage error, and