![EMC2 VNXe3150 Hardware Information Manual Download Page 18](http://html1.mh-extra.com/html/emc2/vnxe3150/vnxe3150_hardware-information-manual_2399841018.webp)
16
EMC VNXe3150 Hardware Information Guide
Overview
2U, 25 (2.5-inch) disk drive DPE
shows the location of the disk drives and the status LEDs in a 2U, 25 (2.5-inch)
disk drive DPE.
Figure 7 Example of the VNXe3150 platform with a 2U, 25 (2.5-inch) disk drive DPE (front view)
Disk drive ready/activity
(location 3)
Note: The disk drive LED (a
left or right triangle symbol)
points to the disk drive that
it refers to.
Blue
On
Powering and powered up
Blinking, mostly
on
Disk drive is on with I/O activity
Blinking at
constant rate
Disk drive is spinning up or down
normally
Blinking, mostly
off
Disk drive is powered up but not
spinning
Note: This is a normal part of the
spin-up sequence, occurring
during the spin-up delay of a
slot.
—
Off
Disk drive is powered down
Table 1 Example of a VNXe3150 platform with a 2U, 12 (3.5-inch) DPE and the disk drive LEDs
LED
Color
State
Description
1
2.5-inch SAS disk drive
1
1. The VNXe3150 platform also supports 6-Gb/s NL-SAS or Flash drives. For more information about the disk
drives supported in the VNXe3150, refer to the
EMC
®
VNXe™ Series Storage Systems Disk and OE Matrix
document.
4
Disk drive fault LED (amber)
2
DPE fault LED (blue), amber if faulted
5
Disk drive ready/activity LED (blue)
3
DPE power status LED (blue)
1
4
VNX-000276
5
2
3