Specifications - NMEA / IEC COM Module RS-422 / RS-485
PCA200828-1
45
IND100129-263
SPECIFICATIONS
Note: All specifi cations are subject to change without prior notice!
Please visit www.hattelandtechnology.com for the latest electronic version.
2/2
3/4
5-pin Isolated NMEA COM
“RS-422/RS-485”
5 4 3 2 1
PIN 01 TxD- Transmit Data Negative
PIN 02 TxD+ Transmit Data Positive
PIN 03 GND Isolated Ground
PIN 04 RxD- Receive Data Negative
PIN 05 RxD+ Receive Data Positive
*Pin 1,2,3,4=RS-422/485 Full Duplex (4-wire)
*Pin 1+4, 2+5 = RS-485 Half Duplex (2-wire)
Connect TxD and RxD pair-wise:
TxD- to RxD-, TxD+ to RxD+.
Note: Confi guration of options for ECHO of
transmitted data and to force the transmitter to
always active is available in BIOS.
RS-422 / RS-485 FULL DUPLEX
120Ω
DE (Data Enable)
External Device
Termination Ω
at end of cable
External Device
TX
TX
RX
RX
120Ω
Termination Ω
at end of cable
120Ω
120Ω
Termination Ω
at end of cable
Termination Ω
at end of cable
TX
External Device
TX
External Device
RX
RX
Pin 1: TxD- (Z)
Pin 2: TxD+ (Y)
Pin 5: RxD+ (A)
Pin 4: RxD- (B)
1
1
1
2
2
2
4
4
4
5
5
5
*
Note: 120Ω termination on TX pins are rarely needed, unless cable is long or enviroment is very noisy.
*
COM Ports are identifed in the Operating System
(example Microsoft
®
Windows
®
10) as:
A = COM6, B = COM7, C = COM8, D = COM9.
(COM ports are not reserved nor locked by BIOS. COM Port numbering may
differ depending on OS used and customized solutions. Use the Operating
System functions to determine actual port numbering, if problems arise).
Our units are based on an isolated RS-485 interface with enhancements to
meet NMEA standard. It is recommended connecting the ground wire since it
will help protect the system in event of fast transient voltage and most likely
also help improve signal integrity in the system.
For slow changing or DC offset our system will most likely work without the
ground wire. If this wire is not connected, our units are more sensitive to fast
transient voltage at the connectors. (The “isolated Ground” wire will help
absorb this energy).
Summary of Contents for HATTELAND HT B30G STC M Series
Page 9: ...9 General...
Page 13: ...13 Installation...
Page 36: ...36 This page left intentionally blank...
Page 37: ...37 Specifications...
Page 53: ...53 Technical Drawings...
Page 57: ...57 Technical Drawings Accessories...
Page 67: ...67 IND100132 478 SF 41 20 Technical Drawings Mounting Rails Kit 20 inch...
Page 68: ...68 IND100132 479 SF 41 26 Technical Drawings Mounting Rails Kit 26 inch...
Page 72: ...72 This page left intentionally blank...
Page 73: ...73 Appendixes...
Page 111: ...111 Appendix IND100077 24 User Notes...
Page 113: ...113 Revision History IND100077 178...
Page 114: ...Hatteland Technology AS www hattelandtechnology com Enterprise no NO974533146...