DATASHEET
Hatteland Technology AS | www.hattelandtechnology.com | Enterprise no: NO974533146
1 x CAN, 2 channels, CAN Module with CO-Processor
Manufacturer:
Hatteland Technology AS
Product:
CAN Module with CO-Processor
Typenumber:
ZIA0001310-B
Last Revised:
16 Apr 2020
Revision#:
24
CAN Module with CO-Processor (NXP LPC1756) is a USB to dual isolated CAN interface board. This card will mainly be integrated,
electrical and mechanical by factory default for Series X G1/G2 Panel Computers and selected Stand-alone Computers. The Hatteland
Technology CAN Module is delivered with software download functions and standard API, SAE J2534, which allow the user to add their
own functions, such as real time critical functions, and high level CAN protocol. The CAN Module can operate as a standalone unit,
which can be configured to operate independent of application software and hardware. This allow the user to use the CAN Module for
time and safe critical operations.
Cost effective CAN solution, Withstand marine requirements, General and open architecture that will allow the end customer to modify
and handle the source code, General CAN interface support, NMEA2000, J1939, CANOpen.
Description:
Specifications
Note: Product below for illustration only. Location of module and product size/design may differ. Connector/pinning remain the same.
Illustration and Pinning:
X8
CAN1
X9
CAN2
1 2 3 4
1 2 3 4
4-pin Terminal Block 3.81
Pinout Assignments
69
IND100241-13
Appendix
5-pin Digital Output Module
“Safety Signal Relay”
3 A
X1
DIG
OUT
1 2 3 4 5
PIN 01 X1 - Out:
011
COM (Common
Center Terminal)
PIN 02 X1 - N/C
Not Connected
Not in use
PIN 03 X1 - Out:
014
NO (Normally Open)
PIN 04 X1 - N/C
Not Connected
Not in use
PIN 05 X1 - Out:
012
NC (Normally Closed)
4+4 pin CAN I/O Module, 2 channels
Type Number “HT 00254 OPT-A1”
3 A B
X8
CAN1
X9
CAN2
1 2 3 4
1 2 3 4
Pin 01 X8 - Can1:
081
In Low
Pin 02 X8 - Can1:
082
Out Low
Pin 03 X8 - Can1:
083
In High
Pin 04 X8 - Can1:
084
Out High
Pin 01 X9 - Can2:
091
In Low
Pin 02 X9 - Can2:
092
Out Low
Pin 03 X9 - Can2:
093
In High
Pin 04 X9 - Can2:
094
Out High
8-pin Digital Output / Input Module
“Solid State Relay”
3 A
X1
DIG
OUT
X1
DIG
IN
1 2 3 4
1 2 3 4
Pin 01 X1 - Out:
041
Out +
Pin 02 X1 - Out:
042
Out -
Pin 03 X1 - Out:
031
COM (Common Center
Terminal) *
Pin 04 X1 - Out:
032
NO (Normally Open)*
* IEC 60950 Compliant, 48VDC
Pin 01 X1 - In:
052
+24VDC
Pin 02 X1 - In:
053
GND (Ground)
Pin 03 X1 - In:
061
+24VDC
Pin 04 X1 - In:
062
+Input
10-pin Digital Output / Input & Serial Module
“Mechanical Relay &
COM (isolated RS-422/485)
”
3 A
X1
DIG
OUT
X7
SER
I/O
1 2 3 4 5
1 2 3 4 5
PIN 01 X1 - Out:
021
COM (Common Center
Terminal)
PIN 02 X1 - N/C
Not Connected / Not used
PIN 03 X1 - Out:
024
NO (Normally Open)
PIN 04 X1 - N/C
Not Connected / Not used
PIN 05 X1 - Out:
022
NC (Normally Closed)
PIN 01 X7 - In:
71
Rx+ (Receive Data +)
PIN 02 X7 - In:
72
Rx- (Receive Data -)
PIN 03 X7 - Out:
73
Tx+ (Transmit Data +)
PIN 04 X7 - Out:
74
Tx- (Transmit Data -)
PIN 05 X7 - GND:
75
SGnd (Signal Ground)
10+10 pin RS-422 / RS-485 NMEA Module
Type Number “PCA100293-1”
3 A B
6 7 8 9 10
1 2 3 4 5
6 7 8 9 10
1 2 3 4 5
PIN 01 TxD- Transmit Data Negative
PIN 02 TxD+ Transmit Data Positive
PIN 03 GND Isolated Ground
PIN 04 RxD- Receive Data Negative
PIN 05 RxD+ Receive Data Positive
PIN 06 TxD- Transmit Data Negative
PIN 07 TxD+ Transmit Data Positive
PIN 08 GND Isolated Ground
PIN 09 RxD- Receive Data Negative
PIN 10 RxD+ Receive Data Positive
RS-485 Half Duplex (2-wire) Confi guration:
Connect TX and RX pair-wise:
TX- to RX-, TX+ to RX+.
*Note: The jumper for “force of transmitter” is
open by factory default. For some custom
models this jumper is preset to closed (active),
in that case unit has to be opened and jumper
set to open to allow Half Duplex mode.
10-pin RS-422 / RS-485 Module
“RS-422/RS-485 SCOM Buzzer”
1
2 B
2 4 6 8 10
1 3 5 7 9
PIN 01* RxD+ Receive Data Positive
PIN 02 GND Ground
PIN 03* RxD- Receive Data Negative
PIN 04 +5V
+5V Out
PIN 05* TxD+ Transmit Data Positive
PIN 06 BUZ- Buzzer Control Negative
PIN 07* TxD-
Transmit Data Negative
PIN 08 BUZ+ Buzzer Control Positive
PIN 09 GNDR
Ground 100Ω
PIN 10 GND Ground
*Pin 1,3,5,7 = RS-485 Full Duplex (4-wire)
*Pin 5,7 = RS-485 Half Duplex (2-wire)
• Number of CAN interfaces
2 independent channels isolated from each other
• Version
CAN 2.0B
• Isolation
Galvanic isolation 2kV, CAN1 to CAN2 and port to chassis
• Protection
- Continuous short circuit signal to signal
- Continuous short circuit to isolated GND
- Continuous shorts to ±27V
• ESD rating on CAN bus
ESD rating of ±12kV Human body model
• Min Baud rate
50 kbit/s*
• Max baud rate
500 kbit/s*
*Note: Available Baud Rates are defined in/by the respective protocols. Customized solutions are possible, contact our Sales Department.
• Address mode
11/29bit
• Terminating
No termination on PCB, user will put them in connector
• PCB Connector
(SCD 3.81/08/90F 3.2SN BK BX) (Do not connect to this, use Terminal Block)
• Cable connector
2 x
(BCZ 3.81/04/180F SN BK BX)
Terminal Block Connector (see illustration below)
• Cable
Twisted pair, no ground
• Recommended Cable Thickness Minimum 22 AWG - Maximum 20 AWG
• Supported protocols
SAE J2534 Standard Data Bus Interface
• Power Consumption
Max 204mA @ 5V
• Supported OS
Embedded Enterprise (WEE):
Microsoft® Windows® Server 2003/2008/2008R2 (Eng),
Microsoft® Windows® 2003/2008/2008R2 (Eng), Microsoft® Windows® 7 Professional/Ultimate
(Eng, SP1), Windows® 10 IoT Enterprise 2016 LTSB.
Linux:
openSUSE® 11.4, Fedora™ 15, Ubuntu® 10.04 LTS, Ubuntu® 12.04 LTS.
Note: Listed Operating Systems above are hardware/platform dependent. Please check datasheet for specific unit if OS is supported.
•
Test and certificate
Hatteland Technology standard (tested / type approved by the following classification societies):
IEC 60945 4th
(EN 60945:2002),
IACS E10
,
EU RO MR
- Mutual Recognition,
ClassNK
- Nippon Kaiji Kyokai
• Relevant Documentation:
https://www.hattelandtechnology.com/hubfs/pdf/misc/doc101357-1_hd_can_module_programmer_guide_windows.pdf
https://www.hattelandtechnology.com/hubfs/pdf/misc/doc101356-1_hd_can_module_programmer_guide_linux.pdf
https://www.hattelandtechnology.com/hubfs/drivers/can_gw_application_note_package.zip
Summary of Contents for Hatteland HD 12T21 MMC Series
Page 7: ...7 This page left intentionally blank...
Page 9: ...9 General...
Page 18: ...18 This page left intentionally blank...
Page 19: ...19 Installation...
Page 41: ...41 Operation...
Page 44: ...44 This page left intentionally blank...
Page 45: ...45 Specifications...
Page 65: ...65 Specifications Accessories...
Page 69: ...69 Technical Drawings...
Page 76: ...76 This page left intentionally blank...
Page 77: ...77 Technical Drawings Accessories...
Page 106: ...106 This page left intentionally blank...
Page 107: ...107 Appendixes...
Page 120: ...120 Appendix IND100077 24 User Notes...
Page 124: ...Hatteland Technology AS www hattelandtechnology com Enterprise no NO974533146...