4.
Actuate the manual operating lever to drive the finger
guard downwards.
Turn the upper die all the way into the adapter nut and
tighten with the fingers.
5.
Loosen the right screw for the lower die with a
screwdriver.
6.
Turn out the screw until it is no longer visible in the
hole.
7.
Insert the lower die into the hole and press up to the
stop.
8.
Tighten the screw for the lower die and then check the
adjustment as described in Section 5.1.
Faulty adjustment causes poor results and can damage