background image

 

P a g e

 | 

12

 

 

8.

 

CONTROL AND  DISPLAY PANEL 

8.1

 

OVERVIEW 

The panel include the below display or control function to monitor and control the pump running status.  

a)

 

Clock:

 Real Time Clock display 

b)

 

Running Status:

 Running speed and power rating display  

c)

 

Pre-set Speed:

 3 pre-set running speeds. 

d)

 

Function settings:

 

Real time clock, 3 pre-set speeds, 2 schedule settings, NO flow, self- priming 

settings, SVRS and Freeze protection 

e)

 

Error display:

 Overcurrent, Overvoltage, Under-voltage, Overheating fault code. 

f)

 

Auto-recovery:

 After an overcurrent, Overvoltage, Under-voltage, Overheating or Power failure, the 

settings will be restored as before the error. 

g)

 

Power failure recovery

: When there is a power is interrupt, the pump will be restored as before 

when power resume.  

h)

 

Wi-Fi :  

Wi-Fi

 

ready indication

 

after start up 

i)

 

RS485 Connection

:

 

external automation control over MODBUS 

 

 

CONTROLLER  DISPLAY 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for SPV150

Page 1: ...SUPER POWER With Wi Fi and MODBUS Swimming Pool Variable Speed Pump USER MANUAL NSF only apply for NSF version...

Page 2: ...2 RS485 SETTING FOR RS 485 VERSION 12 1 SLAVE ADDRESS 18 12 2 BAUD RATE 19 13 WIFI SETTING FOR WIFI VERSION 19 14 FREEZE PROTECTION 19 15 FIRMWARE VERSION AND DATE 19 16 SYSTEM RESET TO FACTORY DEFAUL...

Page 3: ...gas piping and conduit within 1 5 m 5 ft of inside walls of swimming pool spa or hot tub Never open the inside of the drive motor enclosure There is a capacitor bank that holds a mains supply voltage...

Page 4: ...cember 19 2008 with a single submerged suction outlet shall use a suction outlet cover that meets ASME ANSI A112 19 8a and either A A SVRS meeting ASME ANSI A112 19 17 and or ASTM F2387 or B A properl...

Page 5: ...te that put less strain on the complete installation such as filtration sanitization and plumbing It reduces the wear and tear factor and resulting in a cost saving to the pool owner Wireless Wi Fi co...

Page 6: ...Performance Curve Code Model Voltage Frequenc y Max Load Current Connection ID OD Input Power Horse power RPM 88029807 SPV150 220 240V 50 60Hz 5 9 5 4A 1 5 2 50mm 63mm 1 30 kW 1 5 hp 800 3400 RPM 9023...

Page 7: ...in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision 4 INSTALLATION 4 1 Piping I...

Page 8: ...rcuit Interrupt GFCI having a rated residual operating current not exceeding 30 mA If the RCD GFCI device trips it means there is fault on the power line or motor Do not use this pump Disconnect the p...

Page 9: ...OUND Connect the power wires to these terminals according to the electrical code For single phase 220 240Vac 50Hz the pump is shipped with power cord and there is no need to wire the power cord just n...

Page 10: ...I Check the filter and other equipment for proper installation verifying all clamps and connections are properly installed as per the manufacturer s instructions III Open any shut off valves on the su...

Page 11: ...is placed not properly the transparent Lid and Lid nut will not fit well and air leakage should occur v Clean and inspect the Lid s O ring ring reinstall on the transparent Lid vi Cleantheringgrooveon...

Page 12: ...eds 2 schedule settings NO flow self priming settings SVRS and Freeze protection e Error display Overcurrent Overvoltage Under voltage Overheating fault code f Auto recovery After an overcurrent Overv...

Page 13: ...e 800 3400rpm Default 2E off Range on off Default 2O 0 00 Range 00 00 23 59 Default 2F 0 00 Range 00 00 23 59 Default 2S 2400 Range 800 3400rpm Default 3S 3400 Range 800 3400rpm Default PL 2 Range 1 2...

Page 14: ...P in RPM Press Mode again will display the power consumption P in Watt Press Mode again to display the clock CL 9 2 CLOCK SETTING Caution Clock must be set as local time to ensure the pump can work as...

Page 15: ...digital speed value will flash Press or to adjust the speed Press Mode to save setting or press Speed 3 for cancel Repeat above for Speed 2 and Speed 3 setting 9 5 SETTING SCHEDULE When the display b...

Page 16: ...00 Press Speed 1 and Speed 2 to shift between Hour and Minute The adjustable value digital is flashing Press or to adjust the value Press Mode to save setting or press Speed 3 for cancel Press or to a...

Page 17: ...dule timer and speed will be resumed when it is start over bypressing the Start Stop to run again e The scheduled settings and auto recovery cannot contradict each other When there is an error the var...

Page 18: ...m 30 999 seconds iv SVRS Reset Speed is the pump rotation speed for SVRS is function Adjustable range is from 800 3400rpm Default setting is 800rpm is not recommended to change v SVRS Enable Disable d...

Page 19: ...d temperature Then the function will be triggered the pump will run according to the freeze protection speed and time The function will stop if the ambient temperature higher than the threshold temper...

Page 20: ...to recovery The Auto recovery page will display the error details during the first 5 seconds and the countdown details during the following 5 seconds Press Start Stop button to cancel the countdown du...

Page 21: ...RORS When the controller is not working an error code will be shown on the controller display E g Er OV Press the Start Stop button to restore the controller The common error codes are the following E...

Page 22: ...ich is a virtual domain name without internet connection Or by typing IP address 192 168 8 1 to access 20 3 APPLICATION INTERFACE The user interface can do all the PUMP setting and programming as the...

Page 23: ...P a g e 23 Page 1 Page 2...

Page 24: ...necessary The variable speed pump Wi Fi can be set to connect to Home Network Router to extend the control distance and easy access Access Emaux WIFI Type IP address 192 168 8 1 8088 to access the Wi...

Page 25: ...s located at the side of the VS drive and should be connect to MODBUS controller by a cable connector assemble only connector without cable is provided as below figure How to make RS 485 cable assembl...

Page 26: ...ump body 1 7 89021307 Drain Plug With O ring 2 8 02010245 O Ring for Diffuser 1 9 01112081 Diffuser 1 10 89020719 Screw for impeller with O ring 1 11 01311058 Impeller For SPV150 EPV150 1 12 E020001 3...

Page 27: ...tion or discharge line Leakage or air into suction system Impeller clogged Leakage of water at the shaft Shaftseal requiresreplacement Low pump capacity Valve in the suction or discharge line partly c...

Page 28: ...ngth of time vii Damage caused by water freezing inside the product viii Accident damage fire natural disaster or other circumstances outside the control of Emaux ix Items repaired or altered in any w...

Page 29: ...r technical operations Emaux is not liable for any loss of time inconvenience incidental expenses such as labour cost phone calls legal cost or material cost incurred in connection with the replacemen...

Reviews: