Appendix B: Technical data
B-1 General data (mechanical)
Housing/construction
Plastic housing,
With cable glands
Dimensions (W x H x T)
Approx. 157 x 117 x 57 mm
Weight
Approx. 600 g
Cable connection
Screw terminals; 0.14 ... 1.5 mm² (solid wire);
use core ferrules for flexible cable.
Screening
Connect cable screen to the cable gland.
Protection
IP 65
Ambient temperature
-30 °C ... +60 °C
Mounting
Using corrosion-protected screws where possible
Climatic conditions
Suitable for outside installation
B-2 Power supply
Device battery
Lithium battery module, 3.6V,
16.5 Ah; Order no.: 73015774,
13.0 Ah usable
The min. service life of eight years is guaranteed for the following
standard operating
mode
:
Measurement cycle
20 s
Operating cycle
300 s (5 minutes)
Mode Input 1
1 (pulse input)
Display active
1 hour per month
Interface active
15 minutes per month
Ambient temperature
T
A
= -10...+50 °C
B-3 Pulse / signal inputs
Two digital inputs with common ground (negative pole) for reed contacts, transistor
switches.
Each input can be parameterised and sealed separately.
Designation
DE1, DE2
Nominal data
F
When connecting the TC210 in Ex Zone 1, the limits quoted in the certificate of
conformance must also be followed (see Chap. A-2 ).
Summary of Contents for TC210
Page 2: ...Temperature Volume Corrector TC210 2 ELSTER Handel GmbH ...
Page 8: ...Temperature Volume Corrector TC210 8 ELSTER Handel GmbH ...
Page 51: ...TemperatureVolume Corrector TC210 ELSTER HANDEL GmbH 51 ...
Page 52: ...Temperature Volume Corrector TC210 52 ELSTER Handel GmbH ...
Page 62: ...Temperature Volume Corrector TC210 62 ELSTER Handel GmbH ...
Page 63: ...TemperatureVolume Corrector TC210 ELSTER HANDEL GmbH 63 Appendix ...
Page 66: ...Temperature Volume Corrector TC210 66 ELSTER Handel GmbH A 2 Certificate for Ex Zone 1 ...
Page 67: ...TemperatureVolume Corrector TC210 ELSTER HANDEL GmbH 67 ...
Page 68: ...Temperature Volume Corrector TC210 68 ELSTER Handel GmbH ...