Temperature-Volume Corrector TC210
38
ELSTER Handel GmbH
3.3.2 System
AD
Address Designation / value
Unit
Access DC
BAT.R
2:404
Remaining bat. life
M
-
15
MRL.T
5:224_1 Measurement range lower temperature limit
°C
C*
8
MRU.T
5:225_1 Measurement range upper temperature limit
°C
C*
8
T.F
6:311_1 Temperature substitute value
°C
S*
8
TARG
3:424
Ambient temperature range
°C
C*
8
Tb
6:312
Standard temperature
K
C*
8
TYP.T
5:223
Type of temperature sensor
-
C*
8
SN.T
5:222
Serial number of temperature sensor
-
C*
8
Pb
7:312
Standard pressure
bar
C*
8
ST.CL
4:170
Status of customer's lock: Status / close
-
K
7
Cod.C
4:171
Customer's combination, enter / change
-
K
11
VERS
2:190
Software version
-
-
3
CHK
2:191
Software checksum
-
-
4
MCYC
1:1F0
Measurement cycle time
s
C*
8
DAYb
2:141
Day boundary
h
C*
8
ADJ.T
1:452
Clock adjustment factor
-
C*
8
*
= The displayed value can only be changed via the interface.
(For legend see page 28)
The two values marked in grey are user-specific, i.e. the user can himself set which values
are displayed in this list. The factory settings are the above values. The values which can
be set at this point can be taken from the data list (
→
Appendix C:).
The setting of the values to be displayed occurs by entering the addresses of the values to
be displayed with the parameterisation software "WinPADS" under the addresses "6:1C2"
and "8:1C2".
BAT.R Remaining battery service life
The calculation of the remaining battery service life occurs in dependence of the
consumed capacity (which is measured) and a consumption expected for the fu-
ture (which gives the remaining battery service life). If
BAT.R
is less than 3
months, the message "9" (
→
3.3.1.1) is displayed in the system status and "BATT"
(
→
2.1) flashes in the display.
Recalculation of the remaining battery service life is carried out automatically after
the entry of a new battery capacity
BAT.C
(
→
3.3.3).
The settings of the measurement cycle MCYC (
→
3.3.2), operating cycle OCYC
(
→
Appendix C:), input mode and display switch-off (
→
Appendix C:) are taken
into account during the computation of the remaining battery service life. Future
operating conditions, e.g. changing the settings, duration of readouts or frequency
of key operations cannot be foreseen however and therefore lead to a correspond-
ing uncertainty for the displayed remaining battery service life. For data readouts,
a mean future duration of 15 minutes per month is estimated.
Summary of Contents for TC210
Page 2: ...Temperature Volume Corrector TC210 2 ELSTER Handel GmbH ...
Page 8: ...Temperature Volume Corrector TC210 8 ELSTER Handel GmbH ...
Page 51: ...TemperatureVolume Corrector TC210 ELSTER HANDEL GmbH 51 ...
Page 52: ...Temperature Volume Corrector TC210 52 ELSTER Handel GmbH ...
Page 62: ...Temperature Volume Corrector TC210 62 ELSTER Handel GmbH ...
Page 63: ...TemperatureVolume Corrector TC210 ELSTER HANDEL GmbH 63 Appendix ...
Page 66: ...Temperature Volume Corrector TC210 66 ELSTER Handel GmbH A 2 Certificate for Ex Zone 1 ...
Page 67: ...TemperatureVolume Corrector TC210 ELSTER HANDEL GmbH 67 ...
Page 68: ...Temperature Volume Corrector TC210 68 ELSTER Handel GmbH ...