TemperatureVolume Corrector TC210
ELSTER HANDEL GmbH
41
3.3.3 Service
AD
Address Designation / value
Unit
Access DC
CLR
4:130
Clear status register
-
S
2
-
1:1F7
Display test
-
-
1
CP.I1
1:253
cp value Input 1
1/m³
C
7
CP.I2
2:253
cp value Input 2
1/m³
S
7
CP.O1
1:611
cp value Output 1
1/m³
C*
8
CP.O2
2:611
cp value Output 2
1/m³
S*
8
SAVE
1:131
Save all data
-
S
2
BAT.C
1:1F3
Battery capacity
Ah
S
8
ST.SL
3:170
Status of supplier's lock: Status / close
-
S
7
Cod.S
3:171
Supplier's combination, enter / change
-
S
11
CLR.V
2:130
Clear counters
-
C
2
FRZ
1:1FE
Freeze
-
S
2
CLR.X
1:130
Initialise device
-
C
2
Md.O1
1:605
Mode for Output 1
-
C*
8
SC.O1
1:606
Source Output 1
-
C*
8
SP.O1
1:607
Status pointer, Output 1
-
C*
8
STAT
1:100
Momentary overall status
-
-
5
*
= The displayed value can only be changed via the interface.
(For legend see page 28)
The four values marked in grey are user-specific, i.e. the user can himself set which values
are displayed in this list. The factory settings are the above values. The values which can
be set at this point can be taken from the data list (Appendix C:).
The setting of the values to be displayed occurs by entering the addresses of the values to
be displayed with the parameterisation software "WinPADS" under the addresses "9:1C2"
to "12:1C2".
CLR
Clear status register
With this function all the status register content (alarms and warnings) can be
cleared (see Chapter 2.4.5 for procedure). If the alarm or warning states are still
present, they are again directly entered as messages.
-
Display test
The display flashes to test all segments.
CP.I1 cp value Input 1
Pulse constant (parameter of the connected gas meter) for conversion of the
pulses counted on Input 1 into the volume counter
V
(
→
3.1); the increase in vol-
ume is directly accepted into the total actual volume
VT
(
→
3.1). (See Chapter
2.4.3 for the principal procedure for the change on the device.)
CP.I1
indicates how many pulses correspond to the volume of 1 m
3
.
Summary of Contents for TC210
Page 2: ...Temperature Volume Corrector TC210 2 ELSTER Handel GmbH ...
Page 8: ...Temperature Volume Corrector TC210 8 ELSTER Handel GmbH ...
Page 51: ...TemperatureVolume Corrector TC210 ELSTER HANDEL GmbH 51 ...
Page 52: ...Temperature Volume Corrector TC210 52 ELSTER Handel GmbH ...
Page 62: ...Temperature Volume Corrector TC210 62 ELSTER Handel GmbH ...
Page 63: ...TemperatureVolume Corrector TC210 ELSTER HANDEL GmbH 63 Appendix ...
Page 66: ...Temperature Volume Corrector TC210 66 ELSTER Handel GmbH A 2 Certificate for Ex Zone 1 ...
Page 67: ...TemperatureVolume Corrector TC210 ELSTER HANDEL GmbH 67 ...
Page 68: ...Temperature Volume Corrector TC210 68 ELSTER Handel GmbH ...