TemperatureVolume Corrector TC210
ELSTER HANDEL GmbH
45
With the aid of the WinPADS Parameterisation Software the access rights (
→
2.5) men-
tioned here can be changed for each output with an appropriately open lock. In this re-
spect there are the following alternatives:
-
Changes to the settings only possible subject to the calibration lock.
-
Changes to the settings possible subject to the supplier's and calibration locks.
-
Changes to the settings possible subject to the customer's, supplier's and calibration locks.
SC.O1 Source for Output 1
The setting of the sources for the outputs can only be carried out via the optical
interface with the aid of the WinPADS parameterisation software.
This value is only of significance if the mode
Md.O...
of the same output is set to
"1" (volume pulse output) (the same also applies to
SC.O2
,
→
Appendix C:). De-
pending on this, the following settings for
SC.O…
are practicable:
- for mode "1" (volume pulse output)
SC.O...
Meaning
00002:300_0 Vb
Standard volume, undisturbed
00002:301_0 VbD Standard volume, disturbance quantity
00002:302_0 VbT Standard volume, total quantity (undis disturbed)
00004:300_0 V
Actual volume, undisturbed
00004:301_0 VD
Actual volume, disturbed
00004:302_0 VT
Standard volume, total quantity (undis disturbed)
The period duration and pulse duration can be set individually for each output via
the optical interface under the addresses "1:617", "2:617" (period duration) or
"1:618", "2:618" (pulse duration) as a multiple of 125 ms. The period duration must
always be greater than the pulse duration.
If a mode other than "1" is set,
SC.O...
has no significance.
Summary of Contents for TC210
Page 2: ...Temperature Volume Corrector TC210 2 ELSTER Handel GmbH ...
Page 8: ...Temperature Volume Corrector TC210 8 ELSTER Handel GmbH ...
Page 51: ...TemperatureVolume Corrector TC210 ELSTER HANDEL GmbH 51 ...
Page 52: ...Temperature Volume Corrector TC210 52 ELSTER Handel GmbH ...
Page 62: ...Temperature Volume Corrector TC210 62 ELSTER Handel GmbH ...
Page 63: ...TemperatureVolume Corrector TC210 ELSTER HANDEL GmbH 63 Appendix ...
Page 66: ...Temperature Volume Corrector TC210 66 ELSTER Handel GmbH A 2 Certificate for Ex Zone 1 ...
Page 67: ...TemperatureVolume Corrector TC210 ELSTER HANDEL GmbH 67 ...
Page 68: ...Temperature Volume Corrector TC210 68 ELSTER Handel GmbH ...