Readiness for operation
20
NOTE
Damage caused by incorrect installation of the water tank!
Only insert the water tank with the cover closed.
Only top up with soft water.
Make sure that no dirt gets into the water tank.
3.4.2
USE OF A CONDENSATION HOOD
An optional condensation hood is available for the Eloma Backmaster. It is fully
automatic and activated by the in-store baking oven.
The steam and vapours are condensed during baking by air-cooled plate
condensers.
INFORMATION:
Further options (e.g. frames, mixed frames, consoles) are available.
3.4.3
INSTALLATION OF PROCONNECT COMMUNICATION
INFORMATION:
The device must be in standby mode. Otherwise, switch off the device.
1.
Establish the communication connection between the PC and Backmaster
as a point-to-point (LAN) with the respective connection cable.
–
by connecting a USB stick.
–
2.
Set the device address on the ProConnect to the device address of the
Backmaster:
Menu/Settings/Device address
–
3.
Select the appropriate connection in the ProConnect device properties,
creating a new profile as necessary.
INFORMATION:
In the setting dialogues for the device address and interface you have the
option of testing the communication.
Refer to the ProConnect instructions for further information.
3.4.4
NETWORK CONNECTION WITH A KITCHEN CONTROL SYSTEM OR BAKING
CONTROL SYSTEM
A network connection using a kitchen control system or baking control system is
possible if certain hardware and software requirements are met.
Please contact Eloma Customer Service.
Summary of Contents for EB 30
Page 17: ...Readiness for operation 17 Fig 2 Screen after unexpected deactivation e g power failure...
Page 72: ...Maintenance comments notes 72 11 MAINTENANCE COMMENTS NOTES...
Page 73: ...Maintenance comments notes 73...
Page 74: ...Maintenance comments notes 74...
Page 75: ...Maintenance comments notes 75...