![Elnec DATAMAN-40PRO User Manual Download Page 105](http://html1.mh-extra.com/html/elnec/dataman-40pro/dataman-40pro_user-manual_2395135105.webp)
PG4UW
Labels are identifiers for each no-empty line of input file. They are used for addressing each
line of file. The labels should be unique within the file. Addressing lines of file means, that the
required start label entered by user defines line in input file from which serial values reading
starts.
datafilename
- defines name of data file, which contains serialization data. When serialization
requires new serial value, the data file will be loaded by standard PG4UW "Load file"
procedure to PG4UW buffer. File format can be binary or Hex file (Intel Hex etc.). The auto-
recognition system recognizes proper file format and forces load of file in the right file format.
Data filename is relative to parent (playlist) serialization file.
Example of playlist serialization file:
;---- following file header is required -----------------
FILETYPE=PG4UW SERIALIZATION PLAYLIST FILE
;----- references to serialization data files
[nav1] file1.dat
[nav2] file2.dat
[nav3] file3.dat
...
[label n] filex.dat
;-------- end of file ------------------------
For more detailed and fully functional example of serialization type From-file playlist, look the
example files placed in the PG4UW installation directory in Examples\ subdirectory as
following:
<PG4UW_inst_dir>\Examples\Serialization\fromfile_playlist_example\
The typical path can look like this:
C:\Program Files\Dataman\Programmer\Examples\Serialization\fromfile_playlist_example\
You can test the serialization by following steps:
1. start PG4UW
2. you need to have our programmer connected and correctly found in PG4UW
3. select wished device, the best are devices with erasable memory, (not OTP memory)
4. select dialog from menu Device | Device Options | Serialization
5. Set the From-file mode and in the panel From-file mode options select our example
serialization file fromfile_playlist.ser
6. click the OK button to accept the new serialization settings
8. run "Program" device operation
You can see at the serialization indicating labels in the main window of PG4UW and also in
info progress window during device programming and repeating of programming.
Additional operation with used files
This group box contains three types of operation. User can select one of the operation to do
with used serialization data files in Playlist From-file mode. Following operation are available:
•
option Do nothing
program does not make any operation with used serialization data files
•
option Move used file to specified directory
105
Summary of Contents for DATAMAN-40PRO
Page 7: ...Quick Start Introduction 7...
Page 12: ...Quick Start 12...
Page 15: ...Detailed description Detailed description 15...
Page 16: ...DATAMAN 448PRO2 16...
Page 29: ...DATAMAN 48PRO2 DATAMAN 48PRO2C DATAMAN 48PRO2 DATAMAN 48PRO2C 29...
Page 44: ...DATAMAN 40PRO 44...
Page 53: ...DATAMAN MEMPRO DATAMAN MEMPRO 53...
Page 60: ...Setup 60...
Page 71: ...PG4UW PG4UW 71...
Page 138: ...PG4UWMC 138...
Page 148: ...Common notes 148...
Page 159: ...Troubleshooting and warranty Troubleshooting and warranty 159...