12
2.1
Settings in semi-automatic mode
(½Auto)
If no active spray programme is running, so is the
semi-automatic mode automatically active. It
allows to work without a spray-program. In order
to display all measurements correctly in the
display area, the following settings need to be
made:
Number of nozzles
The number of nozzles for each nozzle ring is
shown separately in the top part of the screen
(order is clockwise, starting with the bottom
left nozzle ring).
To adjust the number of nozzles, press this
top area and a window will open (Fig. 10),
where the position of the nozzle rings with the
number of nozzles is displayed in graphic
form (bottom left to bottom right). Press one
of the nozzle rings (=selection fields) to define
a new number of nozzles.
Row width
Enter the row width in meters.
l/ha (optional)
The quantity in litres per hectare to be applied.
If the check box in the “l/ha” window is checked, then by clicking on the Sprayer output
field (a small distance from the check box), the desired quantity can be entered using
the number keypad. With this setting, it is also possible in semi-automatic mode to
regulate the pressure in the event of changes to the speed of travel.
km/h
The target speed of the sprayer during spraying is entered here in km/h. (Small
deviations in speed are taken into consideration as the vehicle is moving and
compensated for automatically).
Note: When the speed limiter function is active, then the value entered here (minus 0.2
km/h) is used as the threshold value. (For more information see Setup → chapter 6.8
“Minimum speed”)
Pressure in Bar:
The
working
pressure
calculated
by
the
programme
is
displayed.
The value cannot be adjusted. If you wish to change the pressure, the above-mentioned
parameters must be changed.
Nozzle type
The type of nozzle used (ATR or ISO) can be selected in the corresponding selection
box (under “Nozzles, right”, Fig. 9). The nozzle colour can be chosen in the preceding
field.
Fig. 10: Selecting the number of nozzles