Troubleshooting aerial EEC-0132
V1.1
Troubleshooting
Category
Problem
Possible Cause
Diagnostic Action
Corrective Action
Outrigger
Leg creeps up
under load or
down during
storage.
Pilot check valve
defective or
Worn seals
inside cylinder.
Clean or replace
check valve or
replace seals.
Outrigger
Leg will not
lower.
Bent let causing
mechanical bind.
Replace leg.
Valves
A lack of
pressure on
boom valve bank
only.
Unloader spool
stuck in the
unload position.
Build up pressure by
dead-ending outrigger
cylinder and release.
Check pressure
filter. Remove
unloader spool and
clean if necessary.
Valves
Pressure will
drop at low RPM,
unit is very slow.
Main pump is
worn or trans.
torque converter
is slipping.
Measure pump flow
rate.
Replace pump or
repair.
Emergency
Pump
Will not activate
at ground station
or remote.
Circuit breaker
tripped.
Test light at
emergency pump to
check for voltage with
switch activated.
Replace circuit
breaker.
Emergency
Pump
Pump speed will
work from
ground control
but not from
remote.
Broken remote
switch, wire
from platform to
plug, plug to
boom terminal,
terminal at
boom to panel
terminal.
Check wire continuity
from point to point.
Bypass switch to check
for operation.
Use spare wire, or
replace switch.
Summary of Contents for Traffic Safety Service L60
Page 2: ...Updated March 10 2020...
Page 5: ......
Page 37: ...Platform Safety hireach EEC 0145 V1 1 Platform Safety...
Page 125: ......
Page 126: ......
Page 127: ......
Page 128: ......
Page 129: ......
Page 130: ......
Page 131: ......
Page 132: ......
Page 133: ......
Page 134: ......
Page 140: ...Bolt Torque EEC 0016 V1 2 Bolt Torque...
Page 152: ...Platform Level System EEC 0137 V1 0 Platform Leveling System...
Page 182: ...4 HYDRAULIC SCHEMATIC...
Page 194: ...16 EXPLODED ISOMETRIC ASSEMBLY DRAWING...
Page 207: ......
Page 208: ......
Page 209: ......
Page 210: ......
Page 212: ...Appendix B Parts Index ELLIOTT Built for You L60 Operator s Manual B 1...